Comparison of synthetic hydroxyapatite and porous polyethylene implants in eviscerated rabbit eyes.

نویسندگان

  • Silvana Artioli Schellini
  • Mariangela E A Marques
  • Carlos Roberto Padovani
  • Eulazio M Taga
  • Romualdo Rossa
چکیده

PURPOSE Synthetic hydroxyapatite and porous polyethylene (Polipore) spheres were placed in rabbits' eviscerated cavities to evaluate tissue reaction and volume maintenance. METHODS Fifty-six Norfolk albino rabbits underwent unilateral evisceration and implantation of synthetic hydroxyapatite (H group, 28 animals) or porous polyethylene spheres (P group, 28 animals). Postoperative reactions, animal behavior, and socket conditions were monitored. Light microscopy and morphometric evaluation with statistical analysis of the exenterated orbits were performed at 7, 15, 30, 60, 90, 120, and 180 days. Scanning electron microscopy was appraised 7, 60, and 180 days after surgery. RESULTS Two animals from the H group and 1 from the P group had extrusion 7 days after surgery. Throughout the experimental period, the synthetic hydroxyapatite caused more inflammation than the porous polyethylene material. Ingrowth in the sphere occurred 7 to 15 days after the surgery in both groups, and the tissue reaction became denser at approximately 60 to 90 days, when bony metaplasia began in the H group. Volume maintenance was better in the P group and with a smaller pseudocapsule surrounding the implanted sphere than in the H group. CONCLUSIONS Clinical findings demonstrated mild inflammation inside the sphere and in the pseudocapsule surrounding it and better cavity volume maintenance in the P group animals. The authors consider porous polyethylene a more suitable material than synthetic hydroxyapatite for use in anophthalmic cavity reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LETTERS TO THE EDITOR Re: “Comparison of Synthetic Hydroxyapatite and Porous Polyethylene Implants in Eviscerated Rabbit Eyes”

I am concerned by the implications of a recently published article by Schellini et al. regarding synthetic hydroxyapatite (HA). I object to their statement: “The authors consider porous polyethylene a more suitable material than synthetic hydroxyapatite for use in anophthalmic cavity reconstruction.” They fail to make it clear that the synthetic HA implant used in their study was vastly differe...

متن کامل

Comparative Study of Bone Repair Using Porous Hydroxyapatite/ β-Tricalcium Phosphate and Xenograft Scaffold in Rabbits with Tibia Defect

Background: Bone tissue engineering requires materials that are biocompatible, mechanically suited for bone function, integrated with the host skeleton, and support osteoinduction of the implanted cells for new bone formation. The aim of this study was to compare the osteogenic potential of xenograft with hydroxyapatite/β- tricalcium phosphate (HA/β-TCP) scaffold. Methods: New Zealand rabbits (...

متن کامل

Six cases of bacterial infection in porous orbital implants.

BACKGROUND We present 6 cases of bacterial infection that developed after porous orbital implant surgery. CASES Five patients with hydroxyapatite implants showed lid swelling, discharge, and suppurative granuloma 14 days to 3 years after surgery. The hydroxyapatite implants were removed 14 days to 41 months postoperatively, and synthetic porous polyethylene orbital implants were inserted. Thi...

متن کامل

Bone Tissue Response to Plasma Sprayed Hydroxyapatite Coatings: An In Vivo Study on Rabbit Femoral Condyles

     In this study, hydroxyapatite was coated on titanium substrates by plasma spraying process. A well-known porous and lamellar microstructure was found in the lateral a...

متن کامل

Detection of Osteogenesis in Explanted Synthetic Hydroxyapatite-Silicone Orbital Implants Using 3D X-Ray Microscopy

Hydroxyapatite orbital implants are widely used in the treatment of post-nucleation socket syndrome. The porous hydroxyapatite serves as a matrix for vascular tissue ingrowth. We investigate the degree of fibro-vascular tissue integration and the presence of osteogenesis within the porous hydroxyapatite part of the orbital implants. For comprehensive imaging, all implants were prepared using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic plastic and reconstructive surgery

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2003