Test-retest reproducibility of 50 kHz linear-electrical impedance myography.

نویسندگان

  • Seward B Rutkove
  • Kyungmouk S Lee
  • Carl A Shiffman
  • Ronald Aaron
چکیده

OBJECTIVE Electrical impedance myography (EIM) is a method for evaluating muscle in which high-frequency, low-intensity alternating current is applied to a body region and the resulting surface voltage pattern over a muscle of interest is measured. In this study, the reproducibility for the simplest of these techniques, 50 kHz linear-EIM, was assessed for three muscles. METHODS Fifty kilohertz linear-EIM was performed on the biceps, quadriceps, and tibialis anterior of 30 normal subjects ranging in age from 21 to 90 years, and the major outcome variable, the spatially averaged phase (thetaavg), measured. The measurements were repeated within 250 days and comparisons between the two data sets made. RESULTS Reproducibility, as measured by the intraclass correlation coefficients for all three muscles, was very high at 0.970, 0.971, and 0.938 for biceps, quadriceps, and tibialis anterior, respectively. Variability between measurements was on average 4.2% for all muscle combined, with an upper limit of 16.8%. CONCLUSIONS Fifty kilohertz linear-EIM demonstrates excellent test-retest reproducibility. SIGNIFICANCE These results support the view that 50 kHz linear-EIM has the potential to be used as a simple, fast, and non-invasive measurement for the assessment of disease status, either as part of individual patient care or as a surrogate outcome measure in clinical trials work.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical impedance myography for the assessment of children with muscular dystrophy: a preliminary study.

Electrical impedance myography (EIM) provides a non-invasive approach for quantifying the severity of neuromuscular disease. Here we determine how well EIM data correlates to functional and ultrasound (US) measures of disease in children with Duchenne muscular dystrophy (DMD) and healthy subjects. Thirteen healthy boys, aged 2-12 years and 14 boys with DMD aged 4-12 years underwent both EIM and...

متن کامل

A Technique for Performing Electrical Impedance Myography in the Mouse Hind Limb: Data in Normal and ALS SOD1 G93A Animals

OBJECTIVE To test a method for performing electrical impedance myography (EIM) in the mouse hind limb for the assessment of disease status in neuromuscular disease models. METHODS An impedance measuring device consisting of a frame with electrodes embedded within an acrylic head was developed. The head was rotatable such that data longitudinal and transverse to the major muscle fiber directio...

متن کامل

Guidelines to electrode positioning for human and animal electrical impedance myography research

The positioning of electrodes in electrical impedance myography (EIM) is critical for accurately assessing disease progression and effectiveness of treatment. In human and animal trials for neuromuscular disorders, inconsistent electrode positioning adds errors to the muscle impedance. Despite its importance, how the reproducibility of resistance and reactance, the two parameters that define EI...

متن کامل

Alterations in Localized Electrical Impedance Myography of Biceps Brachii Muscles Paralyzed by Spinal Cord Injury

This study assessed electrical impedance myography (EIM) changes after spinal cord injury (SCI) with a localized multifrequency technology. The EIM measurement was performed on the biceps brachii muscle at rest condition of 17 cervical SCI subjects, and 23 neurologically intact subjects as control group. The results showed that there was a significant decrease in muscle reactance (X) and phase ...

متن کامل

A portable system for the assessment of neuromuscular diseases with electrical impedance myography.

PRIMARY OBJECTIVE To create a system for the acquisition of multi-angle, multifrequency muscle impedance data. RESEARCH DESIGN Device development and preliminary testing. METHODS AND PROCEDURES The system presented here employs an interrogating signal composed of multiple tones with frequencies between 10 kHz and 300 kHz. The use of a composite signal makes possible measurement of impedance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 117 6  شماره 

صفحات  -

تاریخ انتشار 2006