Assessment of infarct size and severity by quantitative myocardial SPECT: results from a multicenter study using a cardiac phantom.

نویسندگان

  • M K O'Connor
  • L K Leong
  • R J Gibbons
چکیده

UNLABELLED The aim of this study was to determine the reproducibility of measurements of the size and severity of myocardial defects from 99mTc sestamibi cardiac phantom studies performed on multiple different gamma camera systems. METHODS A total of 250 gamma camera systems were evaluated over a 5-y period as part of the validation process of multiple multicenter trials. Each laboratory performed 9 acquisitions of a cardiac phantom. Small myocardial defects (0%-30% of myocardial mass) were placed in the inferobasal region, whereas larger defects (40%-70%) were located in the anterior wall. Five representative short-axis slices were analyzed to determine defect size and severity (i.e., contrast in defect region) using circumferential short-axis count profiles. Defect size and severity were analyzed as a function of the type of collimator, gamma camera system, and type of orbit (180degrees versus 360degrees). RESULTS Of the 250 systems, image data were acquired correctly and showed an acceptable correlation between true and measured defect size in 198 systems. For these systems, the slope of the regression line between true and measured defect size was 1.03 +/- 0.03, with an average absolute error in estimating defect size of 1.7% +/- 0.5% and a correlation coefficient r = 0.99 +/- 0.01. Results were independent of the gamma camera system, type of collimator, and orbit. Contrast in the defect region (minimum count/maximum count) showed a small dependence on collimator resolution and pixel size but was altered significantly by the type of acquisition orbit, with a 360 degrees orbit showing better contrast for defects located in the inferobasal wall than a 180degrees orbit. CONCLUSION Measurement of defect size is independent of the gamma camera system, type of collimator, and orbit. Contrast in small defects located in the inferobasal wall of the heart is affected significantly by the type of acquisition orbit but not by the type of collimator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging

Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Relationship between the optimum cut off frequency for Butterworth filter and lung-heart ratio in 99mTc myocardial SPECT

Background: We investigated whether the lungheart ratio parameter (LHR) can be used to identify the optimum cut off frequency for Butterworth filter in 99mTc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml...

متن کامل

Determination of optimum filter in myocardial SPECT: A phantom study

Background: In myocardial perfusion SPECT imaging, images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. Filters greatly affect quality of nuclear medicine images Materials and Methods: A phantom simulating heart left ventricle was built. About 1mCi of 99mTc was injected into the phantom. Images were taken from this phantom. Some fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 41 8  شماره 

صفحات  -

تاریخ انتشار 2000