A study of professional radiation hazards in CT scan and nuclear medicine workers using GTG-banding and solid stain

نویسندگان

  • Vahid Changizi
  • Mohammad Hossein Alizadeh
  • Akbar Mousavi
چکیده

BACKGROUND CT scan and nuclear medicine exams deliver a great part of medical exposures. This study examined professional radiation hazards in CT scan and nuclear medicine workers. METHODS In a cross sectional study 30 occupationally exposed workers and 7 controls (all from personnel of a laboratory) were selected. Physical dosimetry was performed for exposed workers. Blood samples were obtained from the experimental and control groups. Three culture mediums for each one were prepared in due to routine chromosome analysis using G-banding and solid stain. RESULTS There were significant increased incidence of chromatid gap (ctg) and chromatid break (ctb) with mean±SD frequencies of 3±0.84 and 3.1±1.40 per 100 cells respectively in the nuclear medicine workers versus controls with mean±SD frequencies of 1.9±0.69 and 1.3±0.84 for ctg and ctb, respectively. Chromosome gaps (chrg) were higher significantly in the nuclear medicine population (2.47±0.91) than in controls (1.4±0.9) (p< 0.05). In CT scan group the ctg and ctb were increased with a mean±SD frequency of 2.7±0.79 and 2.6±0.91 per 100 cells respectively compared with control group. The mean±SD frequencies of the chrb were 2.0±0.75 and 0.86±0.690 per 100 cells for exposed workers and control group, respectively. CONCLUSION This study showed chromosome aberrations in peripheral lymphocytes using solid stain method are reasonable biomarker reflecting personnel radiation damage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of professional radiation hazards in CT scan and nuclear medicine workers using GTG-banding and solid stain

  Background: CT scan and nuclear medicine exams deliver a great part of medical exposures. This study examined professional radiation hazards in CT scan and nuclear medicine workers.   Methods : In a cross sectional study 30 occupationally exposed workers and 7 controls (all from personnel of a laboratory) were selected. Physical dosimetry was performed for exposed workers. Blood samples were ...

متن کامل

Evaluation of Chromosomal Aberrations Among Radiotherapy Staff in the City of Tehran Because of Occupational Exposure Using Micronucleus Assay and GTG-Banding

Introduction: Exposure to ionizing radiation as a result of diagnostic, treatment and occupational reasons, has created a remarkable range of cytogenetic damage in the DNA, as the first and main goal of ionizing radiation. The aim of this study is to assess the chromosomal damage in medical radiotherapy workers and its association with effective parameters such as age, sex, duration of employme...

متن کامل

Estimating the radiation dose of non-radiation workers from nuclear medicine patients

Introduction: As a valuable imaging modality, Nuclear Medicine (NM) indications is raising in clinical practice. The remained portion administrated radioactive material in patients’ tissues is a critical issue, especially when the procedure is performed in hospitalized patients, where the non-radiation workers present. The aim of this study was evaluation the dose of non-radia...

متن کامل

Comparison of brain SPECT with 99mTc-MIBI and CT-scan in discriminating of radiation necrosis and brain tumor recurrence [Persian]

Introduction: 99mTc-MIBI has been proposed for use as an imaging agent for various tumors, including breast cancer, lung cancer, lymphomas, melanomas and brain neoplastic lesions. Brain tumors are very common and radiotherapy being major part of treatment following surgery. After radiotherapy, deteriorating clinical status can be due to either radiation necrosis or recurrent tumor. Comput...

متن کامل

Assessment of the individual renal function in chronic unilateral renal obstruction using functional CT as compared to 99mTc-DTPA renal scan

Introduction: The selection of   optimal treatment of obstructive nephrouropathy requires information about the functional status of each kidney. Nuclear renal scanning objectively measure differential renal function, multiple studies have demonstrated the role of assessment of renal perfusion and GFR with triphasic CT. The aim of this study is to assess the role of CT based on renal parenchyma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015