Determination of hematocrit interference in blood samples derived from patients with different blood glucose concentrations.
نویسندگان
چکیده
BACKGROUND We performed a blood glucose meter hematocrit (HCT) interference test with lower sample manipulation requirements by using blood samples from patients with different blood glucose (BG) levels. METHODS Blood from five patients with different BG levels (2.8, 5.6, 8.3, 13.9, 19.4 mmol/liter) was manipulated to contain five different HCT concentrations (35/40/45/50/55%). Each sample was measured three times in parallel with 14 BG testing devices (reference method: YSI 2300 STAT Plus™ Glucose Analyzer). The largest mean deviations in both directions from the reference method (normalized to 100% at 45% HCT) were added as a measure for hematocrit interference factor (HIF). A HIF >10% was considered to represent clinically relevant HCT interference. RESULTS Few devices showed no clinically relevant HCT interference at high/low BG levels: BGStar® (7.2%, 7.3%), iBGStar® (9.0%, 8.6%), Contour® (10.0%, 4.6%), OneTouch® Verio™ 2 (10.0%, 5.2%), and GlucoMen® LX (7.2%, 5.1%). Other devices showed interference at one or both glucose ranges: ACCU-CHEK® Aviva (12.6%, 10.7%), Aviva Nano (7.2%, 10.5%), Breeze2 (3.6%, 30.2%), GlucoCard G+ (12.6%, 7.0%), OneTouch® Ultra®2 (12.6%, 25.6%), FreeStyle Freedom Lite® (9.0%, 11.0%), Precision Xceed (16.2%, 15.3%), and MediTouch® (19.8%, 28.0%). The deviations in all devices were less pronounced in the HCT range of 35-50%. CONCLUSIONS The results of this trial with less sample manipulation (HCT only) confirmed previous examinations with HCT and glucose manipulation. The same devices showed HCT stability as previously observed. Artificial sample manipulation may be less crucial than expected when evaluating HCT interference.
منابع مشابه
Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article
This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...
متن کاملReduction of the interferences of biochemicals and hematocrit ratio on the determination of whole blood glucose using multiple screen-printed carbon electrode test strips.
A practical approach to reduce the interferences of biochemicals and hematocrit ratio (Hct%) in the determination of whole blood glucose using multiple screen-printed carbon electrode (SPCE) test strips is described. SPCE test strips with and without glucose oxidase [i.e., GOD(+)-SPCEs and GOD(-)-SPCEs] were used and the chronoamperometric currents of test glucose solutions with various spiked ...
متن کاملEvaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters.
BACKGROUND Most glucose meter comparisons to date have focused on performance specifications likely to impact subcutaneous dosing of insulin. We evaluated four hospital-based glucose meter technologies for accuracy, precision, and analytical interferences likely to be encountered in critically ill patients, with the goal of identifying and discriminating glucose meter performance specifications...
متن کاملDetermination of Alpha Particles Levels in Blood Samples of Cancer Patients at Karbala Governorate, Iraq
Introduction: Alpha particle emitters are very damaging and harmful when entering into the human body ,if ingested or inhaled , swallowed or absorbed into the lungs or bloodstream . Uranium (238U), Radium (226Ra) and Radon (222Rn) are typical alpha-particle emitters. Material and Methods: we measured the level of alpha particles emitted from 222Rn, 226Ra, and 238U in blood samples of 10 can...
متن کاملEffect of bioactive compounds extracted from euphorbious plants on hematological and biochemical parameters of Channa punctatus.
Channa punctatus was exposed to four different concentrations of Rutin, Taraxerol and Apigenin. Changes in some hematological parameters of Channa punctatus were assessed to determine the influence of these compounds on test fish. Fish were exposed to sublethal concentrations (80% of LC50 of 24h) of these compounds for one week. Control fish were also administered for one week. Thereafter, bloo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2013