Preoperative measurement of thickness of cutaneous melanoma using high-resolution 20 MHz ultrasound imaging: A monocenter prospective study and systematic review of the literature.

نویسندگان

  • Laurent Machet
  • Véronique Belot
  • Michael Naouri
  • Michel Boka
  • Youssef Mourtada
  • Bruno Giraudeau
  • Boris Laure
  • Adeline Perrinaud
  • Marie-Christine Machet
  • Loïc Vaillant
چکیده

Histologic measurement of the thickness of melanoma is a major prognostic factor and governs the size of the surgical excision (1cm for melanomas less than 1 mm thick, 2 cm for melanomas thicker than 2 mm and 3 cm beyond 4 mm). To determine whether high-resolution ultrasound can be used to predict surgical margins and, thus, to operate on patients in a single procedure avoiding further re-excision, we performed a systematic review of studies published from January 1987 to June 2007 and a prospective study. The systematic review selected 14 studies comparing histologic and ultrasound measurements and showing correlation coefficients generally greater than 0.9. Data available from 7 of the 14 studies (total 869 patients) showed predictive values of adequate margins in at least 72% of lesions using preoperative measurement of ultrasound thickness. The prospective study included 31 patients referred with a primary melanoma from March 2005 to March 2007. Ultrasound measurement of thickness was possible except for thin melanomas (<0.4 mm) in areas with marked photoaging, in the plantar zone, and in the case of very thick melanomas exceeding the explored depth (7.6 mm). The average thickness was 1.96 mm measured by ultrasound (SD: 2.15) and 1.95 mm by histology (SD: 2.62) and the Bland and Altman graph showed moderate agreement between ultrasound and histology. Limits of agreement were estimated at -1.4 and +1.8, corresponding to relative limits of agreement of -40 to +80%. Ultrasound predicted appropriate margins (1, 2 or 3 cm wide according to sonometric thickness) in 26 of the 31 subjects (84%, 95% CI 66-95). Preoperative high-resolution ultrasound is a noninvasive examination that can help in choosing appropriate surgical margins and should reduce the need of partial or excisional biopsy before surgery, and the need for further re-excision.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B-Mode Ultrasound Imaging, Doppler Imaging, and Real-Time Elastography in Cutaneous Malignant Melanoma and Lymph Node Metastases

Examination by ultrasonography (US) is a rapid, sensitive, cost-effective, and even portable technique for confirming the presence of tumors. However, US is not routinely used worldwide for the diagnostic work-up of cutaneous malignant melanoma. High-resolution US using a 6-14 MHz or 5-13 MHz linear transducer enables the preoperative assessment of tumor size and thickness. Compared with physic...

متن کامل

The velocity of ultrasound in human primary melanoma tissue - implications for the clinical use of high resolution sonography

BACKGROUND Ultrasonography with 20 MHz frequency can be used to estimate tumour thickness preoperatively in malignant melanoma (MM) of the skin. The vertical invasion depth is the single most important prognostic factor for localised MM, and its preoperative knowledge would be very useful for the planning of surgical procedures. Since ultrasonographic distance measurements directly depend upon ...

متن کامل

Preoperative 15-MHz ultrasound assessment of tumor thickness in malignant melanoma.

BACKGROUND Tumor thickness is of great importance in the management of cutaneous malignant melanoma (MM): this variable not only affects prognosis but is also a key factor in planning surgical margins and selecting candidates for sentinel node biopsy. Breslow depth is the standard histologic measure of thickness, but technological advances have provided imaging techniques such as cutaneous ultr...

متن کامل

Reliability of Ultrasound Imaging of the Trunk Musculature in Athletes with and without Hamstring Injuries

Background: Trunk muscles play an important role in providing both mobility and stability during dynamic tasks in athletes.The purpose of this study was to evaluate the within-day and between-day reliability of ultrasound (US) in measuringabdominal and lumbar multifidus muscle (MF) thickness in athletes with and without hamstring strain injury (HSI).Methods: Fifteen male socce...

متن کامل

High-frequency ultrasonography in monitoring the effects of treatment of selected dermatoses

Introduction: High-frequency ultrasound provides a modern, non-invasive method of skin visualization used for many years in dermatology. In this paper, we present the use of high-frequency ultrasound in monitoring the effects of treatment of selected dermatoses and a review of the literature on this topic. Material and methods: Ultrasound examination of the skin using a 20 MHz linear probe (Der...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 2009