Clinical comparison of the effectiveness of single-file reciprocating systems and rotary systems for removal of endotoxins and cultivable bacteria from primarily infected root canals.

نویسندگان

  • Frederico C Martinho
  • Ana P M Gomes
  • Aletéia M M Fernandes
  • Nádia S Ferreira
  • Marcos S Endo
  • Lilian F Freitas
  • Izabel C G Camões
چکیده

INTRODUCTION This clinical study was conducted to compare the effectiveness of single-file reciprocating systems and rotary systems in removing endotoxins and cultivable bacteria from primarily infected root canals. METHODS Forty-eight primarily infected root canals were selected and randomly divided into 4 groups: WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) (n = 12); Reciproc (VDW, Munich, Germany) (n = 12), ProTaper (Dentsply Maillefer) (n = 12), and Mtwo (VDW) (n = 12). Samples were collected before and after chemomechanical preparation. The irrigation was performed by using 2.5% sodium hypochlorite. A chromogenic limulus amebocyte lysate assay test was used to quantify endotoxins. Culture techniques were used to determine bacterial colony-forming unit counts. RESULTS In the baseline samples (ie, samples collected before chemomechanical preparation), endotoxins and cultivable bacteria were recovered from 100% of the root canal samples. No differences were found in the median percentage values of endotoxin reduction achieved with reciprocating systems (ie, WaveOne [95.15%] and Reciproc [96.21%]) and with rotary systems (ie, ProTaper [97.98%] and Mtwo [96.34%]) (P < .05). Both single-file reciprocating systems (ie, WaveOne [99.45%] and Reciproc [99.93%]) and rotary systems (ProTaper [99.85%] and Mtwo [99.41%]) were effective in reducing the cultivable bacteria (all P < .05). Moreover, the culture analysis revealed no differences in bacterial load reduction (P > .05). CONCLUSIONS Both single-file reciprocating systems (ie, WaveOne and Reciproc instruments) and rotary systems (ie, ProTaper and Mtwo instruments) showed similar effectiveness in reducing endotoxins and cultivable bacteria from primarily infected root canals, but they were not able to eliminate them from all root canals analyzed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی کاهش باکتری داخل کانال با سه روش مکانیکی Instrumentation، K- Type دستی، Race و Profile چرخشی

Statement of Problem: Root canal cleaning and elimination of the source of infection are the most important basis and the main requirements for successful root treatment since the main cause of failure in root treatment is the permeation of bacteria or their products into the periapical tissues. Nowadays, the newly designed and prcsented instruments for canal instrumentation can improve root tr...

متن کامل

Comparison of Cleaning Efficacy and Instrumentation Time of Reciproc and Mtwo Rotary Systems in Primary Molars

Background and Aim: Pulpectomy of primary teeth is commonly performed with hand files and instruments. However, it is a time consuming procedure. Compared to hand files, rotary instrumentation has more advantages. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous mo-lars using Reciproc and Mtwo rotary systems. Materials an...

متن کامل

One-visit versus two-visit root canal treatment: effectiveness in the removal of endotoxins and cultivable bacteria.

INTRODUCTION This clinical study was conducted to compare the effectiveness of 1-visit versus 2-visit root canal treatment in removing endotoxins and cultivable bacteria from primarily infected root canals. METHODS Forty-eight primarily infected root canals were selected and randomly divided into 4 groups: G1, 1% NaOCl; G2, 2% chlorhexidine (CHX) gel; G3, 1% NaOCl + Ca(OH)2; and G4, 2% CHX ge...

متن کامل

Apical extrusion of bacteria when using reciprocating single-file and rotary multifile instrumentation systems.

AIM To evaluate ex vivo, apical bacterial extrusion associated with two reciprocating single-file systems (WaveOne and Reciproc) compared with a conventional multifile rotary system (BioRace). METHODOLOGY Forty-five human single-rooted mandibular incisors were used. Endodontic access cavities were prepared, and root canals were contaminated with an Enterococcus faecalis suspension. Following ...

متن کامل

Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems

Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems Dr. S. Khedmat* - Dr. M. Vahdatifar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Endodontist. Background and Aim: Various rotary systems are available on the market, therefore selection of a proper instr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 40 5  شماره 

صفحات  -

تاریخ انتشار 2014