False negative results in glaucoma detection with Heidelberg Retina Tomograph II
نویسندگان
چکیده
PURPOSE To evaluate the rate of false negative results with the Heidelberg Retina Tomograph (HRT II) in a glaucoma practice. DESIGN Cross-sectional study. METHODS We analyzed the HRTs taken between October 2002 and October 2003 in our glaucoma clinic, and selected the patients who had a good quality image (SD < 40 mu) with a normal Moorfield's Regression Analysis (MRA). A masked independent observer classified those patients as normal, glaucoma suspect, or glaucomatous on the basis of optic disc stereo photos (ODP) and at least 2 consecutive reliable automated perimetries. The diagnosis of glaucoma was based on a glaucomatous optic disc with a congruent, reproducible visual field defect. RESULTS Four hundred and fifty patients who had undergone an HRT examination were analyzed. One hundred and nine patients had an HRT classified as normal on the MRA, and a good quality image. Fifteen of those 109 patients (13.7%) were classified as glaucomatous on the basis of an abnormal ODP with corresponding visual field defect. Seven (6.4%) patients were classified as glaucoma suspect. CONCLUSION Fourteen percent of glaucoma patients with glaucoma remained undetected with the HRT II Moorfield's regression analysis as a sole means to detect glaucoma.
منابع مشابه
A Bayesian framework for glaucoma progression detection using Heidelberg Retina Tomograph images
Glaucoma, the second leading cause of blindness in the United States, is an ocular disease characterized by structural changes of the optic nerve head (ONH) and changes in visual function. Therefore, early detection is of high importance to preserve remaining visual function. In this context, the Heidelberg Retina Tomograph (HRT), a confocal scanning laser tomograph, is widely used as a researc...
متن کاملFactors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements.
AIMS To evaluate the test-retest variability of stereometric parameter measurements made with the Heidelberg retina tomograph (HRT) and Heidelberg retina tomograph-II (HRT-II), and to establish which parameter(s) provided the most repeatable and reliable measurements with both devices. An investigation into the factors affecting the repeatability of the measurements of this parameter(s) was con...
متن کاملComparison of Neuroretinal Rim Area Measurements Made by the Heidelberg Retina Tomograph I and the Heidelberg Retina Tomograph II
PURPOSE To investigate the agreement between neuroretinal rim area (RA) measurements using the Heidelberg Retina Tomograph I (HRT Classic) and Heidelberg Retina Tomograph II (HRT II). To compare apparent RA changes in follow-up series of HRT II topographies when using either an HRT Classic or HRT II mean topography as baseline. DESIGN Cross-sectional study and "no-change," short time series s...
متن کاملFactors affecting the variability of the Heidelberg Retina Tomograph III measurements in newly diagnosed glaucoma patients.
PURPOSE To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were exc...
متن کاملMeasurement variability in Heidelberg Retina Tomograph imaging of neuroretinal rim area.
PURPOSE To investigate the optimal frequency of imaging during follow-up to detect glaucoma progression by characterizing variability (noise) in neuroretinal rim area (RA) measured by Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany). METHODS RA noise was estimated from patient data and characterized by fitting theoretical distributions to the observed data. Multi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2008