Computer - Assisted Navigation for Acetabular Cup Placement : a Single Image Guiding System

نویسنده

  • Heng-Li Huang
چکیده

Incorrect angular placement of the acetabular cup in total hip replacement induces femoral head dislocation, osteolysis, and liner wearing. Some computer-assisted navigation systems to aid acetabular cup placement have been developed in the past decade, but these are not used extensively due to their expense. In this study, a novel algorithm to determine the positions of data points in three-dimensional space from a single-plane image was developed. Based on the validation outcomes, the errors between the true coordinates and the computed coordinates were less than 0.1%. This algorithm was employed in the development of an intrasurgical cup navigation system, which we called the CupNav system. The CupNav system consists of four main hardware components: one digital camera, one laptop, one movable trolley cart, and two self-developed assistant guide frames. In-vitro laboratory validation tests indicated that the possible orientation errors induced by the prototype of CupNav system were less than 1.9 degrees in abduction and 1.4 degrees in anteversion. Although the CupNav system for acetabular cup placement is in the early phase of development, it is clear that the minimal hardware requirement (and hence low cost) of this navigation system makes it suitable for the widespread training and evaluation of inexperienced doctors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study.

Obese populations present challenges for acetabular cup placement during total hip arthroplasty (THA). This study examines the accuracy of acetabular cup inclination and version in the obese patient with robotic-assisted computer navigation. A total of 105 patients underwent robotic-assisted computer navigation THA with a posterior approach. Groups were divided on body mass index (BMI, kg/m(2))...

متن کامل

Accuracy of acetabular cup positioning using imageless navigation

BACKGROUND Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclinat...

متن کامل

Accuracy of Image-based Computer Assisted Surgery in Acetabular Cup Placement for Supine Two-incision Total Hip Arthroplasty

Introduction: Supine patient positioning in conjunction with twoincision minimally invasive surgery (MIS-2 incision) total hip arthroplasty (THA) increases difficulty of accurate and repeatable cup orientation in accordance with pre-operative planning. Investigators have suggested advantages of utilizing computer assisted orthopaedic surgery (CAOS) to successfully eliminate extreme outlying ace...

متن کامل

Computed tomography assessment of image-free navigation-assisted cup placement in THA in an Asian population.

The authors hypothesized that an image-free navigation system would be more accurate than postoperative 3-dimensional (3-D) reconstructed computed tomography (CT) for acetabular cup inclination and anteversion during total hip arthroplasty (THA) in an Asian population. Eighty-one THAs were performed in 72 patients using the OrthoPilot image-free navigation system (B. Braun Aesculap, Tuttlingen,...

متن کامل

Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.

BACKGROUND Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011