Pump pulse-width dependence of grazing-incidence pumped transient collisional soft-x-ray lasers

نویسندگان

  • M. Berrill
  • Y. Wang
  • M. A. Larotonda
  • B. M. Luther
  • V. N. Shlyaptsev
  • J. J. Rocca
چکیده

The output energy dependence of high repetition rate grazing incidence pumped Ni-like Mo, Ni-like Ag, and Ne-like Ti transient collisional soft x-ray lasers on the duration of the pump pulse was studied combining experiments and model simulations. Lasing is observed to occur for a wide range of pump pulse widths e.g., 2 to 18 ps for Ni-like Ag , with maximum output occurring for pump pulses of 4–6 ps FWHM, corresponding to pump intensities of 1.4–2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse duration measurements of grazing-incidence-pumped high repetition rate Ni-like Ag and Cd transient soft x-ray lasers.

We have measured the pulse duration of gain-saturated 13.9 nm Ni-like Ag and 13.2 nm Ni-like Cd transient collisional lasers excited by grazing-incidence-pumping for several pumping conditions. High-resolution streak-camera measurements yielded FWHM pulse durations close to 5 ps for both lasers under optimum pumping conditions. The very high brightness and short pulse duration of these new high...

متن کامل

X-ray Chirped Pulse Amplification: towards GW Soft X-ray Lasers

Extensive modeling of the seeding of plasma-based soft X-ray lasers is reported in this article. Seminal experiments on amplification in plasmas created from solids have been studied in detail and explained. Using a transient collisional excitation scheme, we show that a 18 μJ, 80 fs fully coherent pulse is achievable by using plasmas pumped by a compact 10 Hz laser. We demonstrate that direct ...

متن کامل

Spatial coherence measurements of a 13.2 nm transient nickel-like cadmium soft x-ray laser pumped at grazing incidence.

The spatial coherence of a 13.2 nm transient collisional Ni-like Cd soft X-ray laser pumped at 23 degrees grazing incidence was measured in a series of Young's double-slit experiments. We observed pronounced fringe visibility variations associated with microstructures in the beam's intensity profile. The transverse coherence length was measured to be about 1/20 of the beam diameter and did not ...

متن کامل

Fast capillary discharge plasma as a preformed medium for longitudinally pumped collisional x-ray lasers

Simulations of plasma dynamics in a fast capillary discharge are presented. The temporal dependence of the plasma column’s resistance validates the one-dimensional model that was used in the numerical simulations. Numerical analysis of the laser absorption determines the pump parameter range for efficient excitation of longitudinally pumped transient collisional x-ray lasers. © 2003 Optical Soc...

متن کامل

Characterization of a 10Hz double-pulse non-normal incidence pumped transient collisional Ni-like molybdenum soft x-ray laser for applications

Stable and reliable operation demonstrated and studied with a 10 Hz Ti:sapphire laser system proves the suitability of the double-pulse non-normal incidence pumping geometry for table-top high repetition soft x-ray lasers (SXRL) on the way to applications. In this experiment a nickel-like molybdenum 4d1S0 − 4p1P1 transient collisional soft X-ray laser at 18.9 nm is investigated which is pumped ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007