Primary stability in reversed-anatomy glenoid components.

نویسندگان

  • A R Hopkins
  • U N Hansen
چکیده

Reversed-anatomy shoulder replacement is advocated for patients with poor rotator cuff condition, for whom an anatomical reconstruction would provide little or no stability. Modern generations of this concept appear to be performing well in the short-term to midterm clinical follow-up. These designs are almost always non-cemented, requiring a high degree of primary stability to encourage bone on-growth and so to establish long-term fixation. Six different inverse-anatomy glenoid implants, currently on the market and encompassing a broad range of geometrical differences, were compared on the basis of their ability to impart primary stability through the minimization of interface micromotions. Fixing screws were only included in the supero-inferior direction in appropriate implants and were always inclined at the steepest available angle possible during surgery (up to a maximum of 30 degrees). The extent of predicted bony on-growth was, of course, highly dependent on the threshold for interface micromotion. In some instances an additional 30 per cent of the interface was predicted to promote bone on-growth when the threshold was raised from 20 microm to 50 microm. With maximum thresholds of micromotion for bone on-growth set to 30 microm, the Zimmer Anatomical device was found to be the most stable of the series of the six designs tested herein, achieving an additional 3 per cent (by surface area) of bone on-growth above the closest peer product (Biomet Verso). When this threshold was raised to 50 microm, the Biomet Verso design was most stable (3 per cent above the second-most stable design, the Zimmer Anatomical). Peak micromotions were not a good indicator of the predicted area of bone on-growth and could lead to some misinterpretation of the implant's overall performance. All but one of the implants tested herein provided primary stability sufficient to resist motions in excess of 150 microm at the interface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of baseplate size on primary glenoid stability and impingement-free range of motion in reverse shoulder arthroplasty

BACKGROUND Use of a baseplate with a smaller diameter in reverse shoulder arthroplasty is increasing, especially in patients with a small glenoid or glenoid wear. However, the effect of a smaller baseplate on stability of the glenoid component has not been evaluated. Thus, the purpose of this study was to determine whether a smaller baseplate (25 mm) is beneficial to the initial stability of th...

متن کامل

Tightening force and torque of nonlocking screws in a reverse shoulder prosthesis.

BACKGROUND Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the basepla...

متن کامل

Survival and radiographic analysis of a glenoid component with a cementless fluted central peg.

BACKGROUND Aseptic loosening of glenoid components is a common problem associated with total shoulder arthroplasty and one cause for failure. A new cementless fluted glenoid component was developed and has shown excellent bony ingrowth in a canine model. HYPOTHESIS Clinical utilization of this cementless fluted pegged glenoid component in total shoulder arthroplasty would lower rates of radio...

متن کامل

The effect of component positioning on intrinsic stability of the reverse shoulder arthroplasty.

HYPOTHESIS Anterior instability is one of the most common complications in reverse shoulder replacement. This study hypothesized that intrinsic stability of a reverse prosthesis varies with the degree of version of the humerus and glenoid components. This should provide guidelines on how to best position the implant components to decrease the rate of dislocation. MATERIALS AND METHODS Resista...

متن کامل

Reverse shoulder arthroplasty using a "L" shaped allograft for glenoid reconstruction in a patient with massive glenoid bone loss: case report.

Primary reverse total shoulder arthroplasty (RSA) has demonstrated to relieve pain, restore function and active elevation in patients with Cuff Tear Arthropathy. This condition of muscular imbalance could lead, in the long-term, to morphologic changes of the glenoid's anatomy. Insufficient bone stock of glenoid is a major challenge and without reconstruction, may be inadequate to support a glen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 223 7  شماره 

صفحات  -

تاریخ انتشار 2009