Raman microprobe spectrometer installed in a super-conducting magnet.

نویسندگان

  • Takeyoshi Goto
  • Masayori Suwa
  • Hitoshi Watarai
چکیده

A Raman microprobe spectrometer that could be installed in the bore of a cryogen free super-conducting magnet (10 T) was designed and constructed for the investigation of the external magnetic field effect on the Raman spectra of molecular aggregates in solutions and at interfaces. The performance of the present instrument was demonstrated by measuring the magnetic field effect (0 - 10 T) on the resonance Raman spectra of diprotonated meso-tetra-(sulfonatophenyl)porphine aggregates in an acidic solution. The Raman shifts of the aggregates were not significantly influenced even in 10 T. However, the relative intensity of 1123 cm(-1) peak (nu(C(a)-N)) was interestingly enhanced about 20% under the magnetic fields higher than 2.5 T.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Status of the ALICE Magnet System

Alice is the LHC experiment dedicated to heavy ion (Pb, Ca) physics. Alice will be installed in point 2 of LHC, the former point 2 of LEP. The luminosity at the interaction point will be in the order of 10 (10 for p–p). Consequently, the radiation level in Alice will be comparatively low. We will use the existing infrastructure. Therefore, no noticeable civil engineering work will be necessary....

متن کامل

Large Aperture Hexapole Magnets for the Super-FRS LEB Spectrometer

It is proposed to use a magnetic spectrometer [1,2], located behind the Super-FRS [3] in the LEB cave, for experiments with exotic beams at low and intermediate energies (5 to 200 MeV/A) and stopped beams. For the HISPEC/DESPEC [4] experiments where exotic ions are measured in coincidence with gamma spectroscopy at the secondary target MF10, a good mass identification is necessary. This require...

متن کامل

Special Beam Position Monitor with 8-button Electrodes for the Kekb Interaction Region

To maintain the optimum collision condition of the two beams, two special BPMs with 8-button electrodes, called OCTOPOS, were installed inside the super-conducting quadrupole magnets (QCSs) at the interaction region (IR) of KEKB. We have commissioned the OCTOPOS BPMs for simultaneous measurements of both the electron and positron beam positions from their composite signal. A collision orbital f...

متن کامل

Beam Position Monitor System for the Orbit Feedback at the Interaction Region of Kekb

To maintain the optimum collision condition of the two rings, two special BPMs with 8-button electrodes, called OCTPOS, were installed inside the super-conducting quadrupole magnets (QCSs) at the interaction region (IR) of KEKB. Four normal BPMs with 4-button electrodes were incorporated outside the QCSs. We have commissioned the OCTPOS BPMs for simultaneous measurements of both the electron an...

متن کامل

The University of Hawaii Ims 1280 Ion Microprobe

Introduction: In March, 2006, the Hawaii Institute of Geophysics and Planetology expects to take delivery of a new Cameca ims 1280 ion microprobe. The new ion probe will be the centerpiece of the W. M. Keck Cosmochemistry Laboratory and will be used to analyze extraterrestrial materials, including meteorites, interplanetary dust particles (IDPs), and samples returned by NASA missions. The 1280 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 7  شماره 

صفحات  -

تاریخ انتشار 2006