Tumor blood flow measured by PET dynamic imaging of first-pass 18F-FDG uptake: a comparison with 15O-labeled water-measured blood flow.

نویسندگان

  • Nizar A Mullani
  • Roy S Herbst
  • Roger G O'Neil
  • K Lance Gould
  • Bruce J Barron
  • James L Abbruzzese
چکیده

UNLABELLED PET molecular imaging of 15O-labeled water is the gold standard for measuring blood flow in humans. However, this requires an on-site cyclotron to produce the short-lived 15O tracer, which is cost-prohibitive for most clinical PET centers. The purpose of this study was to determine if the early uptake of 18F-FDG could be used to measure regional blood flow in tumors in the absence of 15O-water. METHODS PET scans were obtained in patients being evaluated for tumor perfusion and glucose metabolism in a phase I dose-escalating protocol for endostatin, a novel antiangiogenic agent. A 2-min perfusion scan was performed with a bolus injection of 2,220 MBq (60 mCi) of 15O-water, which was followed by a 370-MBq (10 mCi) dose of 18F-FDG. Four sequential scans of 18F-FDG uptake were acquired, consisting of an early 2-min uptake scan-or first-pass scan-and 3 sequential 15-min late 18F-FDG uptake scans. Regions of interest (ROIs) were drawn on 2 or more tumor sites and on back muscle, as a control ROI, for each patient. Arterial blood concentration was derived from the PET scans by drawing an ROI over a large artery in the field of view. Blood flow was computed with a simple 1-compartment blood flow model using the first 2 min of data after injection. RESULTS Blood flow estimated from the early uptake of 18F-FDG was linearly correlated with 15O-measured blood flow, with an intercept of 0.01, a slope of 0.86, and an R2 regression coefficient of 0.74 (r = 0.86). The 18F-FDG tumor extraction fraction relative to 15O-water averaged 0.86. A preliminary case study of a patient with prostate cancer confirms the utility of the first-pass 18F-FDG blood flow analysis in tumor diagnosis. CONCLUSION These results suggest that the first-pass uptake of 18F-FDG may provide an estimate of perfusion in a tumor within the limitations of incomplete extraction of 18F-FDG compared with 15O-water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of blood flow in regulating insulin-stimulated glucose uptake in humans. Studies using bradykinin, [15O]water, and [18F]fluoro-deoxy-glucose and positron emission tomography.

Defects in insulin stimulation of blood flow have been used suggested to contribute to insulin resistance. To directly test whether glucose uptake can be altered by changing blood flow, we infused bradykinin (27 microgram over 100 min), an endothelium-dependent vasodilator, into the femoral artery of 12 normal subjects (age 25+/-1 yr, body mass index 22+/-1 kg/m2) after an overnight fast (n = 5...

متن کامل

Regional cerebral blood flow measurement with intravenous [15O]water bolus and [18F]fluoromethane inhalation.

In 20 patients with ischemic cerebrovascular disease, classic migraine, or angiomas, we compared paired dynamic positron emission tomographic measurements of regional cerebral blood flow using both [15O]water and [18F]fluoromethane as tracers. Cerebral blood flow was also determined according to the autoradiographic technique with a bolus injection of [15O]water. There were reasonable overall c...

متن کامل

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

Assessment of a statistical AIF extraction method for dynamic PET studies with 15O water and 18F fluorodeoxyglucose in locally advanced breast cancer patients.

Blood flow-metabolism mismatch from dynamic positron emission tomography (PET) studies with [Formula: see text]-labeled water ([Formula: see text]) and [Formula: see text]-labeled fluorodeoxyglucose (FDG) has been shown to be a promising diagnostic for locally advanced breast cancer (LABCa) patients. The mismatch measurement involves kinetic analysis with the arterial blood time course (AIF) as...

متن کامل

18F-FDG PET/CT in the diagnosis of tumor thrombus from anaplastic thyroid carcinoma in a young boy

  Anaplastic thyroid carcinoma is an uncommon, highly aggressive malignancy usually presenting in the elderly. An eighteen year old boy was recently diagnosed as anaplastic carcinoma of the thyroid.  PET/CECT scan performed for staging, revealed a large FDG avid heterogeneously enhancing thyroid mass with bilateral jugular venous thrombosis, which also showed increase...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 49 4  شماره 

صفحات  -

تاریخ انتشار 2008