Acute bronchospasm and resolution captured on dynamic CT
نویسندگان
چکیده
Computed tomography (CT) imaging provides a noninvasive window beneath the skin, defines lung pathology, and facilitates virtual and multimodality fusion interventions. A CT scan of acute bronchospasm is shown during a CT-guided lung intervention. Dynamic or sequential CT imaging can depict and perhaps even quantify acute reversible bronchospasm, and could potentially play a role in better understanding pharmacologic interventions for reactive airways and the resulting effects.
منابع مشابه
The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملInvestigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...
متن کاملDesign and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملTo Express Required CT-Scan Resolution for Porosity and Saturation Calculations in Terms of Average Grain Sizes
Despite advancements in specifying 3D internal microstructure of reservoir rocks, identifying some sensitive phenomenons are still problematic particularly due to image resolution limitation. Discretization study on such CT-scan data always has encountered with such conflicts that the original data do not fully describe the real porous media. As an alternative attractive approach, one can recon...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...