Homogeneity of the 18 QuickSIN lists.

نویسندگان

  • Mead C Killion
  • Patricia A Niquette
  • Gail I Gudmundsen
چکیده

The purpose of this study was to determine the list equivalency of the 18 QuickSIN (Quick Speech in Noise test) lists. Individuals with normal hearing (n = 24) and with sensorineural hearing loss (n = 72) were studied. Mean recognition performances on the 18 lists by the listeners with normal hearing were 2.8 to 4.3 dB SNR (signal-to-noise ratio), whereas the range was 10.0 to 14.3 dB SNR for the listeners with hearing loss. The psychometric functions for each list showed high performance variability across lists for listeners with hearing loss but not for listeners with normal hearing. For listeners with hearing loss, Lists 4, 5, 13, and 16 fell outside of the critical difference. The data from this study suggest nine lists that provide homogenous results for listeners with and without hearing loss. Finally, there was an 8.7 dB difference in performances between the two groups indicating a more favorable signal-to-noise ratio required by the listeners with hearing loss to obtain equal performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Content and procedural learning in repeated sentence tests of speech perception.

OBJECTIVES Repeated testing of speech perception is unavoidable in evaluating the benefits of hearing aids and auditory rehabilitation, but procedural and content learning due to repeated test administration can masquerade as a general improvement in speech perception. A previous study of the speech reception threshold (SRT) in quiet reported procedural learning that was sufficiently large to c...

متن کامل

Improvements in speech understanding with wireless binaural broadband digital hearing instruments in adults with sensorineural hearing loss.

This investigation examined whether speech intelligibility in noise can be improved using a new, binaural broadband hearing instrument system. Participants were 36 adults with symmetrical, sensorineural hearing loss (18 experienced hearing instrument users and 18 without prior experience). Participants were fit binaurally in a planned comparison, randomized crossover design study with binaural ...

متن کامل

Speech recognition in multitalker babble using digits, words, and sentences.

The purpose of this mixed model design was to examine recognition performance differences when measuring speech recognition in multitalker babble on listeners with normal hearing (n = 36) and listeners with hearing loss (n = 72) utilizing stimulus of varying linguistic complexity (digits, words, and sentence materials). All listeners were administered two trials of two lists of each material in...

متن کامل

Unilateral versus bilateral amplification for adults with impaired hearing.

This study compared unilateral and bilateral aided speech recognition in background noise in 28 patients being fitted with amplification. Aided QuickSIN (Quick Speech-in-Noise test) scores were obtained for bilateral amplification and for unilateral amplification in each ear. In addition, right-ear directed and left-ear directed recall on the Dichotic Digits Test (DDT) was obtained from each pa...

متن کامل

Auditory brainstem response to complex sounds predicts self-reported speech-in-noise performance.

PURPOSE To compare the ability of the auditory brainstem response to complex sounds (cABR) to predict subjective ratings of speech understanding in noise on the Speech, Spatial, and Qualities of Hearing Scale (SSQ; Gatehouse & Noble, 2004) relative to the predictive ability of the Quick Speech-in-Noise test (QuickSIN; Killion, Niquette, Gudmundsen, Revit, & Banerjee, 2004) and pure-tone hearing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 17 8  شماره 

صفحات  -

تاریخ انتشار 2006