Wide-field optical coherence tomography based microangiography for retinal imaging

نویسندگان

  • Qinqin Zhang
  • Cecilia S. Lee
  • Jennifer Chao
  • Chieh-Li Chen
  • Thomas Zhang
  • Utkarsh Sharma
  • Anqi Zhang
  • Jin Liu
  • Kasra Rezaei
  • Kathryn L. Pepple
  • Richard Munsen
  • James Kinyoun
  • Murray Johnstone
  • Russell N. Van Gelder
  • Ruikang K. Wang
چکیده

Optical coherence tomography angiography (OCTA) allows for the evaluation of functional retinal vascular networks without a need for contrast dyes. For sophisticated monitoring and diagnosis of retinal diseases, OCTA capable of providing wide-field and high definition images of retinal vasculature in a single image is desirable. We report OCTA with motion tracking through an auxiliary real-time line scan ophthalmoscope that is clinically feasible to image functional retinal vasculature in patients, with a coverage of more than 60 degrees of retina while still maintaining high definition and resolution. We demonstrate six illustrative cases with unprecedented details of vascular involvement in retinal diseases. In each case, OCTA yields images of the normal and diseased microvasculature at all levels of the retina, with higher resolution than observed with fluorescein angiography. Wide-field OCTA technology will be an important next step in augmenting the utility of OCT technology in clinical practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wide-field imaging of retinal vasculature using optical coherence tomography-based microangiography provided by motion tracking.

Optical coherence tomography (OCT)-based optical microangiography (OMAG) is a high-resolution, noninvasive imaging technique capable of providing three-dimensional in vivo blood flow visualization within microcirculatory tissue beds in the eye. Although the technique has demonstrated early clinical utility by imaging diseased eyes, its limited field of view (FOV) and the sensitivity to eye moti...

متن کامل

High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography.

We present high-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography (OMAG) technology. Based on spatial frequency analysis, OMAG is capable of visualizing the vascular perfusion map down to capillary-level resolution. An OMAG system operating at 840 nm is used with an A-scan rate of 27,000 Hz, axial resolution of 8 mum, and sensitivity of 98 dB. ...

متن کامل

Scalable wide-field optical coherence tomography-based angiography for in vivo imaging applications

Recent advances in optical coherence tomography (OCT)-based angiography have demonstrated a variety of biomedical applications in the diagnosis and therapeutic monitoring of diseases with vascular involvement. While promising, its imaging field of view (FOV) is however still limited (typically less than 9 mm(2)), which somehow slows down its clinical acceptance. In this paper, we report a high-...

متن کامل

Evaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion

Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...

متن کامل

Optical coherence tomography based microangiography as a non-invasive imaging modality for early detection of choroido-neovascular membrane in choroidal rupture

INTRODUCTION To evaluate and identify early microvascular changes in patient with choroidal rupture using optical coherence tomography (OCT) based microangiography (OMAG). CASE DESCRIPTION One patient (one eye) with confirmed diagnosis of choroidal rupture after sustained ocular blunt trauma underwent OMAG imaging. OMAG was performed by Zeiss spectral domain OCT-angiography prototype using a ...