The dose makes the medicine.

نویسنده

  • Walter E Stumpf
چکیده

Dose and time considerations in the development and use of a drug are important for assessing actions and side effects, as well as predictions of safety and toxicity. This article deals with epistemological aspects of dose selection by probing into the linguistic and cultural roots for the measure of medicine mediated by the medical doctor. Because toxicity is related to dose, historic and recent views suggest that less can be more. At low, medium and high dose levels, effects can differ not only quantitatively but also qualitatively. Dose-related target activation and recognition of enantiodromic thresholds between beneficial and toxic effects require elucidation of underlying events. Such studies, including hormesis and microdosing, call for extended ADME procedures with high-resolution methods in addition to the current low-resolution approaches. Improved information of drug logistics and target pharmacokinetics enables effective drug selection, dose determination and prediction. It also allows considerations of systems biology [i.e. integral (gestalt) pharmacology] exemplified by the drug homunculus, as in the case of vitamin D, that might lead to new paradigms and drug design.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography

Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...

متن کامل

Evaluation of Patients’ effective dose in nuclear medicine department of Isfahan in order to define a local reference level

Introduction: Nowadays, nuclear medicine (NM) imaging indications in medical practice is raising. A practical step to get closer to the optimization rule is collecting data about patients’ exposure and definition of guidance levels. The aim of this study was definition of local reference level in Isfahan city. Materials and Methods: Questionnaires were given...

متن کامل

Basic investigation on performance of low-density polymer gel dosimeter

Background:  In this study a series of basic dosimetric properties of a low-density (LD) gel dosimeter are investigated. The dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. Materials and Methods: The LD gel was made by mixing the polymer gel with expanded polystyrene spheres. Energy dependence was studied...

متن کامل

InRaDoS: An internal radiation dosimetry computer program

Introduction: Internal radiation dosimetry is important from a radiation protection point of view and can help to optimize the radiation dose delivered to the workers, public, and patients. It has a rather simple protocol but needs a large amount of data. Therefore, it is difficult to do on a routine basis. The use of computer programs makes internal radiation dosimetry simpler...

متن کامل

A Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source

Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose enhancement in the tumors loaded with these materials. Objective: The purpose of this study is to evaluate dose distribution in the presence of 10B, 157Gd and 33S neutron...

متن کامل

EPID in vivo Dosimetry

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Drug discovery today

دوره 11 11-12  شماره 

صفحات  -

تاریخ انتشار 2006