Accuracy and consequences of 3D-fluoroscopy in upper and lower extremity fracture treatment: a systematic review.
نویسندگان
چکیده
OBJECTIVES The aim of this systematic review was to compare the diagnostic accuracy, subjective image quality and clinical consequences of 3D-fluoroscopy with standard imaging modalities (2D-fluoroscopy, X-ray or CT) during reduction and fixation of intra-articular upper and lower extremity fractures. METHODS A systematic literature search was performed in MEDLINE, EMBASE and the Cochrane library. In total 673 articles were identified (up to March 2012). The 19 included studies described patients/cadavers with intra-articular upper/lower extremity fractures and compared 3D-fluoroscopy to standard imaging. The study was performed in accordance with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) guidelines. Diagnostic accuracy was defined by the quality of fracture reduction or implant position and, if possible, expressed as sensitivity and specificity; subjective image quality was determined by the quality of depiction of bone or implants; clinical consequences were defined as corrections in reduction or implant position following 3D-fluoroscopy. RESULTS Ten cadaver- and nine clinical studies were included. A meta-analysis was not possible, because studies used different scoring protocols to express diagnostic accuracy and reported incomplete data. Based on the individual studies, diagnostic accuracy of 3D-fluoroscopy was better than 2D-fluoroscopy and X-ray, but similar to CT-scanning. Subjective image quality of 3D-fluoroscopy was inferior compared to all other imaging modalities. In 11-40% of the operations additional corrections were performed after 3D-fluoroscopy, while the necessity for these corrections were not recognized based on 2D-fluoroscopic images. CONCLUSIONS Although subjective image quality is rated inferior compared to other imaging modalities, intra-operative use of 3D-fluoroscopy is a helpful diagnostic tool for improving the quality of reduction and implant position in intra-articular fractures.
منابع مشابه
The effect of different types of foot orthoses on the biomechanical variables, lower extremity muscular activity and balance in elderly: A systematic review study
Older adults demonstrate increased amounts of postural sway, which may ultimately lead to falls. The purpose of this systematic review was to investigate the effect of different foot orthoses on lower limb biomechanical variables, lower limb muscular activity, and balance in elderly people. Examining texts based on the search on the Magiran, Google Schoolar, Pubmed, Scopus, and SIVILICA sites w...
متن کاملTherapeutic exercises can improve lower extremity functional indexes of people with dynamic knee valgus: A systematic review and meta-analysis
Purpose: One of the most significant contributors to lower extremity degeneration alterations and its effects on balance and sports performance is dynamic knee valgus faulty movement pattern. Different exercise interventions have been conducted to improve dynamic knee valgus. The extensive research and meta-objective analysis aimed to assess how exercise interventions affected people with dynam...
متن کاملMandibular angle fracture following closed extraction of lower third molar: A case report and systematic review
Objectives Mandibular third molar extraction is among the most commonly performed dental procedures. Fracture of the angle of mandible after third molar extraction is a rare complication of this procedure. Case Herein, we report fracture of the right angle of mandible immediately after extraction of mandibular right third molar in a 38-year old healthy female patient, which was surgically mana...
متن کاملClinical application of computer guidance and navigation in orthopaedic trauma surgery at the extremities and the pelvis: a systematic review
examined the feasibility of naviga tion for interlocking procedures of intramedullary nails in fractures of the lower extremity. However, the majo rity of works included patients with injuries of the pelvic ring; computer assisted systems were mainly used to insert cannulated screws, stabilising acetabular fractures or the sacro–iliac joint. Only one publication included computerised treatme...
متن کاملExtremity Fracture Diagnosis Using Bedside Ultrasound in Pediatric Trauma Patients Referring to Emergency Department; A Diagnostic Study
Background This study performed to assess the efficacy of ultrasound in screening upper and lower extremities fractures in comparison with standard X-ray in pediatric trauma patients. Materials and Methods This was a prospective diagnostic study conducted at the emergency department of Imam Khomeini Complex Hospital, Tehran, Iran. All patients with the age under 18-year-old admitted with limb t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of radiology
دوره 81 12 شماره
صفحات -
تاریخ انتشار 2012