Transcatheter aortic valve implantation with the new-generation Evolut R™
نویسندگان
چکیده
BACKGROUND The Medtronic Evolut R (EVR) is a novel transcatheter heart valve designed to allow precise implantation at the intended position and to minimize prosthesis dysfunction as well as procedural complications. Our aim was to compare short-term functional and clinical outcomes of the new EVR with the established Medtronic CoreValve (CV) system. METHODS AND RESULTS Of 151 patients undergoing transfemoral transcatheter aortic valve implantation with a self-expanding valve at our institution between January 2013 and January 2016, 86 were treated with EVR and 65 with CV. Patients treated with EVR had a significantly lower rate of more-than-mild aortic regurgitation and a higher rate of device success. Recapture maneuvers to optimize valve deployment were performed in 22.1% of the EVR procedures. Transvalvular post-procedural gradients were slightly higher in the EVR group, while no differences were observed in the incidence of safety endpoints at 30 days, vascular complications, or need for permanent pacemaker implantation following asystole or complete atrioventricular block. CONCLUSIONS These initial single-center experience data on the short-term outcomes after EVR valve implantation show a substantially reduced rate of more-than-mild paravalvular regurgitation and higher device success, while 30-day safety outcomes were similar to the CV system. Clinical outcome data from long-term follow-up and larger scale multicenter experience are now necessary.
منابع مشابه
Transcatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملTranscatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report
BACKGROUND Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. CASE PRESENTATION We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurren...
متن کاملFirst in Greece Transcatheter Aortic Valve Implantation using the CoreValve Evolut-R Retrievable and Repositionable Bioprosthesis with the InLine Sheath and the EnVeo Loading Guiding Catheter: A Major Advantage for SmallDiameter Access Vessels.
We report the first TAVI procedure in Greece to use the CoreValve Evolut-R (23 mm profile) bioprosthesis with the InLine sheath and the EnVeo loading guiding catheter in a patient with small anatomical characteristics (aortic annulus, access vessel) and severe comorbidities. The procedure was successfully conducted under general anesthesia through a surgically prepared, extensively calcified, l...
متن کاملTranscatheter Tricuspid Valve-In-Ring and Aortic Valve-In-Valve Implantation
Background Transcatheter heart valve (THV) therapies have shown to be an alternative to surgical valve replacement, especially in high-risk patients requiring redo surgery. However, reports of transcatheter-based interventions in tricuspid valve position are scarce. Case Description Here, we report a case of successful concomitant transcatheter aortic valve-in-valve (ViV) and tricuspid valve-...
متن کاملOutcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
BACKGROUND Transcatheter aortic valves can degenerate in a manner similar to surgical bioprostheses. METHODS AND RESULTS Clinical and echocardiographic outcomes of patients who underwent redo transcatheter aortic valve replacement (TAVR) procedures >2 weeks post procedure were collected from 14 centers. Among 13 876 patients, 50 (0.4%) underwent redo TAVR procedure at participating centers. I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2016