Optimization of the cutoff value for the Aspergillus double-sandwich enzyme immunoassay.
نویسندگان
چکیده
BACKGROUND Many health care centers worldwide use the Platelia Aspergillus enzyme immunoassay (PA-EIA; Bio-Rad Laboratories) for diagnosis of invasive aspergillosis (IA). A cutoff optical density (OD) index of 1.5 was originally recommended by the manufacturer, but in practice, most institutions use lower cutoff values. Moreover, a cutoff OD index of 0.5 was recently approved in the United States. In the present study, we set out to optimize the cutoff level by performing a retrospective analysis of PA-EIA values for samples that had been obtained prospectively from adult patients at risk for IA at 2 European health care centers. METHODS In total, 239 treatment episodes were included of which there were 19 episodes of proven IA and 19 episodes of probable IA. Per-episode and per-test analyses and receiver operating characteristic curves were used to determine the optimal cutoff value. RESULTS In the per-episode analysis, lowering the cutoff OD index for positivity from 1.5 to 0.5 increased the overall sensitivity by 21% (from 76.3% to 97.4%) but decreased the overall specificity by 7% (from 97.5% to 90.5%). Requiring 2 consecutive samples with an OD index > or = 0.5 resulted in the highest test accuracy, with an improved positive predictive value. At a cutoff OD index of 0.5, the antigen test result was positive during the week before conventional diagnosis in 65% of cases and during the week of diagnosis in 79.5% of cases. CONCLUSIONS A cutoff OD index of 0.5--identical to the approved cutoff in the United States--improves the overall performance of the PA-EIA for adult hematology patients.
منابع مشابه
Cross-reactivity of Paracoccidioides brasiliensis, Histoplasma capsulatum, and Cryptococcus species in the commercial Platelia Aspergillus enzyme immunoassay.
Cross-reactivity in the Platelia Aspergillus enzyme immunoassay was evaluated using 120 sera from patients with paracoccidioidomycosis, histoplasmosis, and cryptococcosis. At a cutoff value of 0.5, positivity rates were 50%, 67%, and 50%, respectively. The implications for these findings are discussed.
متن کاملDouble Sandwich ELISA Modified Method for the Detection of Clostridium Botulinum Type E
Background & Objective: A very small amount of botulinum toxin can cause death and on the other hand, there is no cure for its poison other than antitoxin. Therefore, a diagnostic method that can detect very small amounts of botulinum toxin in a short time is very important. In this study, rapid and accurate detection of botulinum toxin type E has been performed with the double sandwich ELISA m...
متن کاملCutoff grades optimization with environmental management A case study: Sungun Copper Project
Cutoff grade is a grade used to assign a destination label to a parcel of material. The optimal cutoff grades depend on all the salient technological features of mining, such as the capacity of extraction and of milling, the geometry and geology of the orebody, and the optimal grade of concentrate to send to the smelter. The main objective of each optimization of mining operation is to maximize...
متن کاملSignificance of galactomannan antigen for aspergillosis diagnosis: A review
Invasive aspergillosis is one the major causes of death in hematopoietic and solidtransplantrecipients. One of the most critical problems in medical mycology is theinability to consistently make a convincing and early diagnosis of invasive fungalinfection. Conventional diagnosis methods such as culture-based approaches are limitedby the insufficient accessibility sensitivity and the non-culture...
متن کاملDetection of galactomannan antigenemia by enzyme immunoassay for the diagnosis of invasive aspergillosis: variables that affect performance.
Invasive aspergillosis (IA) is a frequent complication of blood or marrow transplantation. Previous studies have reported that the Aspergillus galactomannan enzyme immunoassay (GM EIA) may be a useful diagnostic tool for IA, but its sensitivity is variable. We examined the performance of the GM EIA in 986 serum samples from 67 patients. Results demonstrated that decreasing the index cutoff for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical infectious diseases : an official publication of the Infectious Diseases Society of America
دوره 44 10 شماره
صفحات -
تاریخ انتشار 2007