A Framework for Evaluating ICA Methods of Artifact Removal from Multichannel EEG
نویسندگان
چکیده
We present a method for evaluating ICA separation of artifacts from EEG (electroencephalographic) data. Two algorithms, Infomax and FastICA, were applied to "synthetic data," created by superimposing simulated blinks on a blink-free EEG. To examine sensitivity to different data characteristics, multiple datasets were constructed by varying properties of the simulated blinks. ICA was used to decompose the data, and each source was cross-correlated with a blink template. Different thresholds for correlation were used to assess stability of the algorithms. When a match between the blink-template and the decomposition was obtained, the contribution of the source was subtracted from the EEG. Since the original data were known a priori to be blink-free, it was possible to compute the correlation between these "baseline" data and the results of different decompositions. By averaging the filtered data, time-locked to the simulated blinks, we illustrate effects of different outcomes for EEG waveform and topographic analysis.
منابع مشابه
EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach
Introduction: Clinicians use several computer-aided diagnostic systems for depression to authorize their diagnosis. An electroencephalogram (EEG) may be used as an objective tool for early diagnosis of depression and controlling it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. Methods: This work proposes a no...
متن کاملDevelopment, validation, and comparison of ICA-based gradient artifact reduction algorithms for simultaneous EEG-spiral in/out and echo-planar fMRI recordings
EEG data acquired in an MRI scanner are heavily contaminated by gradient artifacts that can significantly compromise signal quality. We developed two new methods based on independent component analysis (ICA) for reducing gradient artifacts from spiral in-out and echo-planar pulse sequences at 3 T, and compared our algorithms with four other commonly used methods: average artifact subtraction (A...
متن کاملICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner.
Electroencephalogram (EEG) data acquired in the MRI scanner contains significant artifacts, one of the most prominent of which is ballistocardiogram (BCG) artifact. BCG artifacts are generated by movement of EEG electrodes inside the magnetic field due to pulsatile changes in blood flow tied to the cardiac cycle. Independent Component Analysis (ICA) is a statistical algorithm that is useful for...
متن کاملWavelet-ICA based Denoising of Electroencephalogram Signal
Electroencephalogram (EEG) signals are having very small amplitudes and because of that they can be easily contaminated by different Artifacts. The presence of artifacts makes the analysis of EEG difficult for clinical evaluation. The major types of artifacts that affect the EEG are Power Line noise, eye movements, Electromyogram (EMG), and Electrocardiogram (ECG). Out of these artifacts Power ...
متن کاملEvaluating the efficacy of fully automated approaches for the selection of eyeblink ICA components.
Independent component analysis (ICA) offers a powerful approach for the isolation and removal of eyeblink artifacts from EEG signals. Manual identification of the eyeblink ICA component by inspection of scalp map projections, however, is prone to error, particularly when nonartifactual components exhibit topographic distributions similar to the blink. The aim of the present investigation was to...