An in-vivo comparison of stimulated-echo and motion compensated spin-echo sequences for 3 T diffusion tensor cardiovascular magnetic resonance at multiple cardiac phases
نویسندگان
چکیده
BACKGROUND Stimulated-echo (STEAM) and, more recently, motion-compensated spin-echo (M2-SE) techniques have been used for in-vivo diffusion tensor cardiovascular magnetic resonance (DT-CMR) assessment of cardiac microstructure. The two techniques differ in the length scales of diffusion interrogated, their signal-to-noise ratio efficiency and sensitivity to both motion and strain. Previous comparisons of the techniques have used high performance gradients at 1.5 T in a single cardiac phase. However, recent work using STEAM has demonstrated novel findings of microscopic dysfunction in cardiomyopathy patients, when DT-CMR was performed at multiple cardiac phases. We compare STEAM and M2-SE using a clinical 3 T scanner in three potentially clinically interesting cardiac phases. METHODS Breath hold mid-ventricular short-axis DT-CMR was performed in 15 subjects using M2-SE and STEAM at end-systole, systolic sweet-spot and diastasis. Success was defined by ≥50% of the myocardium demonstrating normal helix angles. From successful acquisitions DT-CMR results relating to tensor orientation, size and shape were compared between sequences and cardiac phases using non-parametric statistics. Strain information was obtained using cine spiral displacement encoding with stimulated echoes for comparison with DT-CMR results. RESULTS Acquisitions were successful in 98% of STEAM and 76% of M2-SE cases and visual helix angle (HA) map scores were higher for STEAM at the sweet-spot and diastasis. There were significant differences between sequences (p < 0.05) in mean diffusivity (MD), fractional anisotropy (FA), tensor mode, transmural HA gradient and absolute second eigenvector angle (E2A). Differences in E2A between systole and diastole correlated with peak radial strain for both sequences (p ≤ 0.01). CONCLUSION M2-SE and STEAM can be performed equally well at peak systole at 3 T using standard gradients, but at the sweet-spot and diastole STEAM is more reliable and image quality scores are higher. Differences in DT-CMR results are potentially due to differences in motion sensitivity and the longer diffusion time of STEAM, although the latter appears to be the dominant factor. The benefits of both sequences should be considered when planning future studies and sequence and cardiac phase specific normal ranges should be used for comparison.
منابع مشابه
Second order motion compensated spin-echo diffusion tensor imaging of the human heart
PURPOSE Myocardial microstructure has been challenging to probe in vivo. Spin echo-based diffusion-weighted sequences allow for single-shot acquisitions but are highly sensitive to cardiac motion. In this study, the use of second-order motion-compensated diffusion encoding was compared with first-order motion-compensated diffusion-weighted imaging during systolic contraction of the heart. MET...
متن کاملDirect comparison of in-vivo and post-mortem spin-echo based diffusion tensor imaging in the porcine heart
Background Spin-echo based cardiac diffusion tensor imaging (DTI) is highly sensitive to myocardial strain [1]. Imaging during systolic contraction requires precise planning of the sequence timing [2]. Second order motion compensated diffusion encoding has recently been proposed for small animal imaging [3] to reduce the impact of myocardial strain on the diffusion tensor. It is the objective o...
متن کاملSpin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart
PURPOSE To compare signal-to-noise ratio (SNR) efficiency and diffusion tensor metrics of cardiac diffusion tensor mapping using acceleration-compensated spin-echo (SE) and stimulated echo acquisition mode (STEAM) imaging. METHODS Diffusion weighted SE and STEAM sequences were implemented on a clinical 1.5 Tesla MR system. The SNR efficiency of SE and STEAM was measured (b = 50-450 s/mm(2) ) ...
متن کاملSecond order motion compensated spin echo cardiac diffusion tensor imaging on clinical MR systems
Background Recently second order motion compensated spin echo (SE) sequences in conjunction with high performance gradient systems have been proposed for diffusion weighted (DWI) [1] and diffusion tensor imaging (DTI) [2,3] of the human in vivo heart. The method allows for free breathing acquisition without requiring dedicated patient feedback systems or other provisions [4], facilitating the t...
متن کاملIn-vivo cardiac DTI: An initial comparison of M012 compensated spin-echo and STEAM
Background In-vivo cardiac diffusion tensor imaging (cDTI) has been performed using a stimulated echo (STEAM) sequence for 20 years [1]. While short diffusion gradients make it motion insensitive, it is strain sensitive and SNR inefficient. Recently a spin-echo (SE) sequence with velocity and acceleration compensated diffusion gradients was demonstrated in rats [2] and healthy volunteers using ...