Caluculating Current Densities and Fields Produced by Shielded Magnetic Resonance Imaging Probes
نویسندگان
چکیده
A method is presented for computing the fields produced by radio frequency probes of the type used in magnetic resonance imaging. The effects of surrounding the probe with a shielding coil, intended to eliminate stray fields produced outside the probe, are included. An essential feature of these devices is the fact that the conducting rungs of the probe are of finite width relative to the coil radius, and it is therefore necessary to find the distribution of current within the conductors as part of the solution process. This is done here using a numerical method based on the inverse finite Hilbert transform, applied iteratively to the entire structure including its shielding coils. It is observed that the fields are influenced substantially by the width of the conducting rungs of the probe, since induced eddy currents within the rungs become more pronounced as their width is increased. The shield is also shown to have a significant effect on both the primary current density and the resultant fields. Quality factors are computed for these probes and compared with values measured experimentally.
منابع مشابه
The modeling of induced current density in eyes from static magnetic fields produce by MR scanner
Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...
متن کاملSoftware for Design NMR Probes Using the Shielded Split Ring and the Shielded Symmetrical Band Resonators
This article presents a software (NMR PROBES) for design NMR probes using closed-forms formulas of the primary and secondary parameters of the shielded split ring [1] and the shielded symmetrical band resonators [2]. These formulas are based on rigorous analysis by finite element method (FEM) [3], [4], method of moment (MoM) [5] and curves fitting techniques. The presented software permits the ...
متن کاملFinite size disc gradient coil set for open vertical field magnets.
A new analytical approach is used in the design of disc-like gradient coils suitable for magnet geometries with main field direction perpendicular to the surface of the disc. An inverse procedure is used to optimize the coil's characteristics, subject to the restrictions imposed by the desired field behavior over a certain set of constraint points inside a predetermined imaging volume. Excellen...
متن کاملShielded biplanar gradient coil design.
An application of the target field method to the design of shielded biplanar gradient coils for magnetic resonance imaging electromagnets is presented. Some specific cases are studied, and optimized geometries are proposed for the axial and transverse gradient coils that eliminate the third- and minimize the fifth-order terms in the magnetic field expansion.
متن کاملDoes Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?
MRI workers are occupationally exposed to static and time-varying gradient magnetic fields. While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- SIAM Journal of Applied Mathematics
دوره 57 شماره
صفحات -
تاریخ انتشار 1997