Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model.

نویسندگان

  • R Materne
  • B E Van Beers
  • A M Smith
  • I Leconte
  • J Jamart
  • J P Dehoux
  • A Keyeux
  • Y Horsmans
چکیده

Various liver diseases lead to significant alterations of the hepatic microcirculation. Therefore, quantification of hepatic perfusion has the potential to improve the assessment and management of liver diseases. Most methods used to quantify liver perfusion are invasive or controversial. This paper describes and validates a non-invasive method for the quantification of liver perfusion using computed tomography (CT). Dynamic single-section CT of the liver was performed after intravenous bolus administration of a low-molecular-mass iodinated contrast agent. Hepatic, aortic and portal-venous time-density curves were fitted with a dual-input one-compartmental model to calculate liver perfusion. Validation studies consisted of simultaneous measurements of hepatic perfusion with CT and with radiolabelled microspheres in rabbits at rest and after adenosine infusion. The feasibility and reproducibility of the CT method in humans was assessed by three observers in 10 patients without liver disease. In rabbits, significant correlations were observed between perfusion measurements obtained with CT and with microspheres (r=0.92 for total liver perfusion, r=0.81 for arterial perfusion and r=0.85 for portal perfusion). In patients, total liver plasma perfusion measured with CT was 112+/-28 ml.min(-1).100 ml(-1), arterial plasma perfusion was 18+/-12 ml.min(-1).100 ml(-1) and portal plasma perfusion was 93+/-31 ml.min(-1).100 ml(-1). The measurements obtained by the three observers were not significantly different from each other (P>0.1). Our results indicate that dynamic CT combined with a dual-input one-compartmental model provides a valid and reliable method for the non-invasive quantification of perfusion in the normal liver.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

Dynamic computed tomography with low- and high-molecular-mass contrast agents to assess microvascular permeability modifications in a model of liver fibrosis.

Interstitial collagen formation and transformation of the fenestrated hepatic sinusoids into continuous capillaries are major ultrastructural changes that occur in liver cirrhosis and fibrosis. These modifications lead to progressive restriction of blood-liver exchanges. The purpose of our study was to evaluate the permeability changes in a model of hepatic fibrosis by using dynamic computed to...

متن کامل

GPU-accelerated voxelwise hepatic perfusion quantification.

Voxelwise quantification of hepatic perfusion parameters from dynamic contrast enhanced (DCE) imaging greatly contributes to assessment of liver function in response to radiation therapy. However, the efficiency of the estimation of hepatic perfusion parameters voxel-by-voxel in the whole liver using a dual-input single-compartment model requires substantial improvement for routine clinical app...

متن کامل

Simulation of Perfusion Flow Dynamics for Contrast Enhanced Imaging

Dynamic Contrast Enhanced Computed Tomography is an imaging tool that aids in evaluating functional characteristics in different stages of disease assessment: diagnostic, treatment effectiveness and monitoring. At the present time, following all the technological advances, there remains no universally validated method of quantitative, non-invasive, perfusion imaging. In order to address this ch...

متن کامل

Feasibility Study of Computational Fluid Dynamics Simulation of Coronary Computed Tomography Angiography Based on Dual-Source Computed Tomography

BACKGROUND Adding functional features to morphological features offers a new method for non-invasive assessment of myocardial perfusion. This study aimed to explore technical routes of assessing the left coronary artery pressure gradient, wall shear stress distribution and blood flow velocity distribution, combining three-dimensional coronary model which was based on high resolution dual-source...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 99 6  شماره 

صفحات  -

تاریخ انتشار 2000