Determination of menadione sodium bisulfite in pharmaceutical preparations by flow-injection on-line photochemical spectrofluorometry.

نویسندگان

  • Q He
  • Z Wang
  • X Cao
  • H Chen
  • Y Ke
چکیده

A flow-injection on-line photochemical spectrofluorometry (FI-PF) was developed for the determination of menadione sodium bisulfite (MSB) using acetone and sodium sulfite as sensitizing reagents. An injected sample band carried by a water stream was on-line merged with a mixed NaOH, Na2SO3 and acetone solution in a "T" connector. It was then driven to pass a knotted PTFE photochemical reactor (0.5 mm i.d. x 200 cm, KR) that was freely coiled around a 6-W low-pressure mercury lamp. While passing the KR, MSB was derived into an intensively fluorescent compound that was on-line delivered into a flow-through cell and detected therein at an emission wavelength of 459 nm and an excitation wavelength of 336 nm. Under optimized conditions a detection limit of 0.38 microg l(-1) was achieved at a sampling rate of 90 h(-1). Eleven determinations of 0.5 mg l(-1) and 0.05 mg l(-1) MSB standard solution gave RSDs of 0.75% and 1.3%, respectively. The calibration curve was linear in the MSB concentration range 0.005-1.5 mg l(-1). The proposed method was successfully applied to assay the MSB content in MSB injection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation by Two Derivative Spectrophotometric Methods

Firstand second-order derivative spectrophotometric methods for the quantitative determination by converting menadione sodium bisulphite (MSB) to menadione (M ) with sodium carbonate were developed and validated in pharmaceutical preparation. The quantitative determination of MSB was carried out by using wavelengths 350 nm (for first-order; 1D) and 355 nm (for second-order; 2D) with the lineari...

متن کامل

GC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation

GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...

متن کامل

GC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation

GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...

متن کامل

Determination of thiamine in pharmaceutical preparations by sequential injection renewable surface solid-phase spectrofluorometry.

Fluorometric determination of thiamine requires the conversion of the analyte to fluorescent thiochrome by hexacyanoferrate(III) oxidation in alkaline solution and the isolation of the produced thiochrome from the reaction medium by solvent extraction. It was observed that thiochrome could be concentrated and separated from the reaction medium by solid-phase extraction. The thiochrome sorpted o...

متن کامل

Validation of a Stability-Indicating Hydrophilic Interaction Liquid Chromatographic Method for the Quantitative Determination of Vitamin K3 (Menadione Sodium Bisulfite) in Injectable Solution Formulation

A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 17 10  شماره 

صفحات  -

تاریخ انتشار 2001