First fully automated immunoassay for anti-Müllerian hormone.

نویسندگان

  • Dieter Gassner
  • Rebecca Jung
چکیده

BACKGROUND The increasing importance of anti-Müllerian hormone (AMH) for the assessment of ovarian reserve requires accurate AMH measurements. There have been conflicting results about the reliability of currently existing manual AMH assays. METHODS Development of a high sensitive, fast and fully automated AMH assay on the Elecsys®/cobas e electrochemiluminescence immunoassay platform. RESULTS Elecsys® AMH is a monoclonal two-site assay used to measure AMH in 50 µL of serum or lithium heparin plasma in about 18 min. Its measuring range is from 0.01 to 23 ng/mL. The assay detects primarily 140 kDa total AMH (proAMH and AMHN,C). Standardization was against the Beckman AMH Gen II. Recovery against the highly cited Immunotech calibration was about 90%. Within-run imprecision coefficient of variation (CV) calculated on 10 serum samples were between 0.5% and 1.8%. Repeatability and intermediate precision calculated on 14 serum samples ranged from 2.6% to 1.7% and 2.9% to 2.1%, respectively. Limit of detection (LoD) [limit of quantitation (LoQ)] was 0.01 ng/mL (0.03 ng/mL). Percent recovery in dilution studies was <10% and after mixing of high and low AMH pools 94% to 103%. Elecsys® AMH, when compared to revised AMH Gen II (or Ansh Labs ultrasensitive AMH ELISA) using 57 female serum samples yielded a correlation coefficient of 0.98 (0.97) and a slope of 0.81 (0.73). There was no evidence for sample instability or variability. Samples stored at 20-25 °C or 2-8 °C up to 7 days showed no significant storage issues. Freeze-thaw cycles or sample storage at -20 °C and -80 °C for up to 9 months was without any effect on measured AMH. CONCLUSIONS Availability of an automated Elecsys® AMH assay offers an attractive alternative to the current manual AMH assays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduced anti-Müllerian hormone (AMH) in mares with hemorrhagic anovulatory follicles

Anti-Müllerian hormone (AMH) has been observed to decrease with the development of hemorrhagic anovulatory follicles (HAFs) in mares. Two studies were conducted to evaluate AMH concentration in mares with HAFs compared to seasonally anoestrous and cyclic mares, and to elucidate changes of AMH with the development of luteinised unruptured follicles (LUFs). In study 1, AMH and progesterone were e...

متن کامل

Serum Anti-Müllerian Hormone Levels in Patients with Epithelial Ovarian Cancer

Objectives. The aim of our study was to examine serum anti-Müllerian hormone (AMH) concentration in ovarian cancer patients in relation to clinicopathological features, such as a pathological subtype of the tumor, (FIGO) stage, grading, and overall 5-year survival. Material and Methods. We enrolled 72 epithelial ovarian cancer patients in our study, aged 45-79 years, who underwent optimal cytor...

متن کامل

BungumL, FranssohnF, BungumM,Humaidan P,GivercmanA.The circadian variation in anti-Müllerian hormone in patients with polycystic ovary syndrome differs significantly from normally ovulating

variation in anti-Müllerian hormone in patients with polycystic ovary syndrome differs significantly from normally ovulating women. PLoS One 2013;9:e68223. Dolleman M, Faddy MJ, van Disseldorp J, van der Schouw TY, Messow CM, Leader B, Peeters PH, McConnachie A, Nelson SM, Broekmans FJ. The relationship between anti-Müllerian hormone in women receiving fertility assessments and age at menopause...

متن کامل

Anti-Müllerian hormone and lifestyle, reproductive, and environmental factors among women in rural South Africa.

BACKGROUND Few data exist regarding anti-Müllerian hormone, a marker of ovarian reserve, in relation to environmental factors with potential ovarian toxicity. METHODS This analysis included 420 women from Limpopo, South Africa studied in 2010-2011. Women were administered comprehensive questionnaires, and plasma concentrations of anti-Müllerian hormone and dichlorodiphenyltrichloroethane were...

متن کامل

Non-equivalence of anti-Müllerian hormone automated assays—clinical implications for use as a companion diagnostic for individualised gonadotrophin dosing

STUDY QUESTION Can anti-Müllerian hormone (AMH) automated immunoassays (Elecsys® and Access) be used interchangeably as a companion diagnostic for individualisation of follitropin delta dosing? SUMMARY ANSWER The Access assay gives systematically higher AMH values than the Elecsys® assay which results in over 29% of women being misclassified to a different follitropin delta dose. WHAT IS KN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2014