Measurement of layer-like hemodynamic trends in scalp and cortex: implications for physiological baseline suppression in functional near-infrared spectroscopy.
نویسندگان
چکیده
A multidetector, continuous wave, near-infrared spectroscopy (NIRS) system is developed to examine whether the hemodynamics of the scalp and brain in adults contain significant layer-like hemodynamic trends. NIRS measurements are made using contrasting geometries, one with four detectors equidistant from a source 33 mm away, and one with detectors collinear with the source (5 to 33 mm away). When NIRS time series are acquired over the prefrontal cortex from resting adults using both geometries, variations among the time series are consistent with a substantially homogeneous two-layer model (p<0.001) and inconsistent with one dominated by heterogeneities. Additionally, when time series measured 5 mm from the source are subtracted from corresponding 33-mm signals via a least-squares algorithm, 60% of the hemoglobin changes are on average removed. These results suggest that hemodynamic trends present in the scalp can contribute significantly to NIRS measurements, and that attempts to reduce this noise by subtracting a simultaneous near-channel measurement using a two-layer model are justified. Such subtractions are then performed on NIRS measurements from two stimulus protocols. For systemic stimulations (Valsalva maneuver), the subtraction cancels the hemodynamic response, as desired. For localized stimulation of the occipital lobe (viewing a flickering pattern), the subtraction isolated a stimulus-correlated hemodynamic feature from background noise.
منابع مشابه
Optical Imaging of the Motor Cortex in the Brain in Order to Determine the Direction of the Hand Movements Using Functional Near-Infrared Spectroscopy (fNIRS)
Introduction: In recent years, optical imaging has attracted a lot of attention from scholars as a non- aggressive, efficient method for evaluating the activities of the motor cortex in the brain. Functional near-infrared spectroscopy (fNIRS (is a tool showing the hemodynamic changes in a cortical area of the brain according to optical principles. The present study has been de...
متن کاملExtended hierarchical Bayesian diffuse optical tomography for removing scalp artifact.
Functional near-infrared spectroscopy (fNIRS) can non-invasively measure hemodynamic responses in the cerebral cortex with a portable apparatus. However, the observation signal in fNIRS measurements is contaminated by the artifact signal from the hemodynamic response in the scalp. In this paper, we propose a method to separate the signals from the cortex and the scalp by estimating both hemodyn...
متن کاملCerebral functional imaging using near-infrared spectroscopy during repeated performances of motor rehabilitation tasks tested on healthy subjects
To investigate the relationship between the frontal and sensorimotor cortices and motor learning, hemodynamic responses were recorded from the frontal and sensorimotor cortices using functional near infrared spectroscopy (NIRS) while healthy subjects performed motor learning tasks used in rehabilitation medicine. Whole-head NIRS recordings indicated that response latencies in the anterior dorso...
متن کاملQuantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model
Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...
متن کاملSignal Processing in Functional Near-Infrared Spectroscopy (fNIRS): Methodological Differences Lead to Different Statistical Results
Even though research in the field of functional near-infrared spectroscopy (fNIRS) has been performed for more than 20 years, consensus on signal processing methods is still lacking. A significant knowledge gap exists between established researchers and those entering the field. One major issue regularly observed in publications from researchers new to the field is the failure to consider possi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 13 3 شماره
صفحات -
تاریخ انتشار 2008