Prediction of response factors for gas chromatography with flame ionization detection: Algorithm improvement, extension to silylated compounds, and application to the quantification of metabolites

نویسندگان

  • Jean‐Yves de Saint Laumer
  • Sabine Leocata
  • Emeline Tissot
  • Lucie Baroux
  • David M. Kampf
  • Philippe Merle
  • Alain Boschung
  • Markus Seyfried
  • Alain Chaintreau
چکیده

We previously showed that the relative response factors of volatile compounds were predictable from either combustion enthalpies or their molecular formulae only [1]. We now extend this prediction to silylated derivatives by adding an increment in the ab initio calculation of combustion enthalpies. The accuracy of the experimental relative response factors database was also improved and its population increased to 490 values. In particular, more brominated compounds were measured, and their prediction accuracy was improved by adding a correction factor in the algorithm. The correlation coefficient between predicted and measured values increased from 0.936 to 0.972, leading to a mean prediction accuracy of ±6%. Thus, 93% of the relative response factors values were predicted with an accuracy of better than ±10%. The capabilities of the extended algorithm are exemplified by (1) the quick and accurate quantification of hydroxylated metabolites resulting from a biodegradation test after silylation and prediction of their relative response factors, without having the reference substances available; and (2) the rapid purity determinations of volatile compounds. This study confirms that gas chromatography with a flame ionization detector and using predicted relative response factors is one of the few techniques that enables quantification of volatile compounds without calibrating the instrument with the pure reference substance. This article is protected by copyright. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Synthetic Phenolic Antioxidants in Biological Fluids Based on Air-assisted Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

An air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an a...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 38  شماره 

صفحات  -

تاریخ انتشار 2015