Bacterial Contamination of Dialysing Fluid of Artificial Kidney.

نویسنده

  • E E KIDD
چکیده

During haemodialysis with the Kolff twin-coil artificial kidney the patient's blood is passed through " cellophane " tubing which is immersed in a dialysing bath. This holds 100 litres of fluid, with an electrolytic composition similar to that of the normal plasma, with an addition of 0.88% glucose. During haemodialysis, urea and other nitrogenous substances appear in increasing quantities. The bath is kept at a constant temperature of 370 C. and it was formerly our practice to change the dialysing fluid every three hours. (In the light of experience, however, we now change the bath at much shorter intervals.) In our early endeavours with this equipment we were disturbed to note an increasing turbidity of the fluid in the bath as dialysis progressed. Knowing that the contents of the dialysing bath constituted an ideal culture medium for some bacterial species, we suspected that the turbidity might be the result of bacterial growth. This led us to make a bacteriological investigation of the contents of the bath. The result of this we are now presenting. The equipment had been in clinical use for approximately two years at the time this inquiry was instituted, and it was customary to subject the equipment only to routine cleaning with soap, detergents, or mild abrasives. Bacterial Contamination of Dialysing Fluid Methods During dialysis 1-ml. samples of the dialysing fluid were examined bacteriologically by means of a viable count using a technique similar to that described by Miles et al. (1938). After incubation at 370 C. for 24 hours at least three drops of a suitable dilution on nutrient agar were used to calculate the number of organisms. Moistened swabs were employed to examine various parts of the dialysing bath and reservoir tank in which the second and third changes of solution were prepared. These swabs were taken after the tank had been cleaned and were plated on nutrient agar and incubated at 370 C. for 24 hours. Results A typical result of the viable counts during a dialysis is shown in Fig. 1. The total count plotted against the time of sampling showed two precipitous falls corresponding to the times when the bath fluid was changed. During the changing of the bath the whole contents cannot be removed by the pump, so that each new bath is necessarily inoculated from its predecessor. Since there were 60,000 organisms per ml. in the first bath of a …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contamination of preservation fluid in kidney transplantation: single-center analysis.

INTRODUCTION Contamination of preservation fluid is common, with a reported incidence of 2.2% to 28.0%, and may be a major cause of early morbidity after transplantation. Herein, we report our experience with routine examination of preservation fluid collected just before implantation, focusing on the rate of contamination and the clinical consequences to recipients. MATERIALS AND METHODS We ...

متن کامل

Clinical impact of bacterial contamination of perfusion fluid in kidney transplantation

Contamination of perfusion fluid (PF) could lead to serious infections in kidney transplant recipients. Preemptive therapy (PE-T) in case of yeast contamination of PF is mandatory. The usefulness of PE-T in presence of bacteria remains unclear. In this study we evaluated the incidence of PF bacterial contamination and the impact of PE-T on clinical outcome. Microbiological data of 290 PF and cl...

متن کامل

Bacterial contamination of four commonly used dental materials

Bacterial contamination of four commonly used dental materials Dr. M. Ghavam* - Dr. M. Aligholi** *- Associate Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- The member of Microbiology Dept. Faculty of Medicine – Tehran University of Medical Sciences. Background and Aim: Bacterial contamination of dental materials and devices used in d...

متن کامل

Comments on "Study of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit"

This letter is regarding the article by Daoudi et al. entitled "Study of bacterial contamination of mobile phones and stethoscopes in Neonatal Intensive Care Unit" published in International Journal of Pediatrics DOI: 10.22038/IJP.2017.25504.2170 (1). The authors have evaluated the microbial contamination of mobile phones and stethoscopes used by medical and paramedical staff. They reported tha...

متن کامل

Frequency of Bacterial Frequency of Bacterial Contamination in Traditional Ice Cream Produced in Arak, Iran (2011)

Abstract Background and Objective: Ice cream is a suitable environment for microbial growth due to its chemical structure, ingredients, and its increased supply and demand. In the absence of hygienic considerations, it can cause poisoning. This study aimed to determine bacterial contamination in traditional ice cream produced in Arak city in 2011. Material and Methods: The samples (n= 30) were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British medical journal

دوره 1 5387  شماره 

صفحات  -

تاریخ انتشار 1964