Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography

نویسندگان

  • Eui-Jong Chung
  • Tae-Yop Kim
  • Jong Min Hwang
  • Sang-Phil Kim
  • Hyun Suk Yang
چکیده

Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transapical access closure of a mechanical mitral prosthesis leak.

A 62-year-old woman with a history of rheumatic mitral valve disease and commissurotomy closed in 1969, implantation of a Shiley biological mitral prosthesis in 1978, and its replacement in 1998 by a No. 25 Bjork mechanical prosthesis, showed symptoms consistent with congestive heart disease and analytical findings indicating hemolytic anemia. Transesophageal echocardiography detected 2 mitral ...

متن کامل

[Hemolytic anemia secondary to paravalvular regurgitation].

Rev Esp Cardiol 2002;55(9):987 987 A 73-year-old woman was admitted for severe anemia 2 months after mitral and aortic cardiac valve replacement with Saint Jude mechanical prostheses. The differential blood count showed macrocytic anemia (hemoglobin 7.1 g/dL; MCV 111 fl; corrected reticulocyte count, 3.5%). The blood smear revealed marked anisopoikilocytosis, intense polychromasia, and abundant...

متن کامل

Coil embolization of a periprosthetic mitral valve leak associated with severe hemolytic anemia.

A55-year-old man presented with severe fatigue, anorexia, and weight loss. His past medical history was significant for diabetes mellitus, severe mitral annulus calcification, aortic and mitral valve replacement, prosthetic mitral valve endocarditis complicated by periprosthetic mitral regurgitation, and repeat mitral valve replacement 2 months before admission. Admission hemoglobin was 6 g/dL ...

متن کامل

Live/real time three-dimensional transesophageal echocardiographic evaluation of mitral and aortic valve prosthetic paravalvular regurgitation.

Thirteen patients already scheduled for surgery for repair of prosthetic paravalvular regurgitation underwent intraoperative real time two-dimensional transesophageal echocardiography (2D TEE) and live/real time three-dimensional transesophageal echocardiography (3D TEE). In all patients, 3D TEE was able to provide more information regarding the location and size of the paravalvular defect as c...

متن کامل

Three-dimensional transesophageal echocardiogram provides real-time guidance during percutaneous paravalvular mitral repair.

A 65-year-old woman with severe paravalvular mitral regurgitation and chronic hemolytic anemia was referred for surgical consultation. Her medical history included rheumatic heart disease with mitral valve replacement in 1977, aortic valve replacement in 1988, and repeat mechanical mitral valve replacement in 2002. Predominant symptoms were New York Heart Association function class III dyspnea ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2012