Lead stuck (frozen) in header: salvage by bone cutter versus other techniques. [email protected].

نویسندگان

  • John D Fisher
  • Peter Lapman
  • Soo G Kim
  • Kevin J Ferrick
  • Jay N Gross
  • Eugen C Palma
  • Alexander Delvecchio
چکیده

It is occasionally difficult to disconnect leads from headers at the time of pulse generator replacement without injuring the fragile leads. Over a 2.5-year period we encountered this problem in six cases (1.7% of pulse generator replacements). The posterior portion of the header was clipped off using an orthopedic bone cutter in four cases. The cut was aligned with the deep end of the lead socket in the header. A metal rod was then used to push the lead out of the socket. Bench testing of alternative methods was done on previously explanted pulse generators that were firmly held in a vice. Motorized microtools were used to drill holes from the end of the header to the deep end of the socket; or with a rotary saw attachment to slice off the back of the header, allowing a retained lead to be pushed out. The latter was also done with a hand held razor saw, and attempts were made with a scalpel. Lead removal in the clinical cases was accomplished quickly in the four cases using the bone-cutter, without trauma to the lead. Bench testing results varied. The bone cutter was the most efficient method for most brands, but was ineffective on one. The motorized tool was difficult to position, produced sprays of plastic particles, and would have been risky in a clinical setting. The razor saw was difficult to use safely, or efficiently, except in some headers that resisted the bone cutter. The scalpel failed except in one "soft header" pacemaker. An orthopedic bone cutter is a useful tool for removing a retained lead from a pulse generator header. Different header designs and materials necessitate knowledge of several lead detachment methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epithelialization Over a Scaffold of Antibiotic-Impregnated PMMA Beads: A Salvage Technique for Open Tibial Fractures with Bone and Soft Tissue Loss When all Else Fails

  The management of soft tissue defects in tibial fractures is essential for limb preservation. Current techniques are not without complications and may lead to poor functional outcomes. A salvage method is described using three illustrative cases whereby a combination of flaps and antibiotic-impregnated polymethylmethacrylate beads are employed to fill the bony defect, fight the infection, and...

متن کامل

Dynamics Analysis on Roadheader Cutting Head Based on LS-DYNA

The dynamic performances of head cutter for boom-type excavator were researched, and the corresponding dynamic equilibrium equations were derived. Based on the explicit dynamics analysis techniques of the Software ANSYS/LS-DYNA, transient dynamic analysis was carried out to simulate the cutting process of head cutter, and the main kinetic parameters were achieved. Finally, the cutting performan...

متن کامل

Short Term Complications and Functional Results of Sarcoma Limb Salvage Surgeries

Background: Limb salvaging surgeries are current surgical treatment of extremity bone sarcomas. Resected bonereplacement consists of two main methods; tumor prosthesis versus structural allograft. Biological reconstruction withan allograft is an economic cheap method in young sarcoma patients, however, the surgeons are more convinced withtumor prosthesis replacement.Methods: We evaluated the sh...

متن کامل

Stage IE Primary Bone Lymphoma:Limb Salvage for Local Recurrence

Background:   Primary bone lymphoma or non-Hodgkin lymphoma of bone is a rare disease. There are only a few case series of stage IE of this condition in medical literature. The aim of this study is to determine the rate of survival   for stage IE after combined modality treatment, the rate of local recurrence, and the results of limb salvage in cases   of local recurrence.     Methods:   We col...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 27 8  شماره 

صفحات  -

تاریخ انتشار 2004