Glenohumeral joint motion after subscapularis tendon repair: an analysis of cadaver shoulder models

نویسندگان

  • Teiichi Sano
  • Mitsuhiro Aoki
  • Yoshitaka Tanaka
  • Tomoki Izumi
  • Mineko Fujimiya
  • Toshihiko Yamashita
چکیده

BACKGROUND As for the surgical treatment of the rotator cuff tears, the subscapularis tendon tears have recently received much attention for the mini-open or arthroscopic repair. The results of surgical repair for the subscapularis tendon tear are satisfactory, but the range of external rotation is reported to be restricted after the repair. The purpose of this study was to evaluate the range of glenohumeral joint motion after repairs of various sizes of subscapularis tendon tears. METHODS Using eight fresh frozen human cadaveric shoulders (mean age at death, 81.5 years), three sizes of subscapularis tendon tear (small, medium, and large) were made and then repaired. With the scapula fixed to the wooden jig, the end-range of glenohumeral motion was measured with passive movement applied through 1.0-Nm torque in the directions of scapular elevation, flexion, abduction, extension, horizontal abduction, and horizontal adduction. The passive end-ranges of external and internal rotation in various positions with rotational torque of 1.0 Nm were also measured. Differences in the ranges among the three type tears were analyzed. RESULTS As tear size increased, range of glenohumeral motion in horizontal abduction after repair decreased gradually and was significantly decreased with the large size tear (P < 0.01). The end-range of external rotation decreased progressively with increasing tear size in every glenohumeral position. The prominent decrease in external rotation (around 40° reduction from intact shoulders) was observed in shoulders after repair of large size tear at 30° to 60° of scapular elevation and abduction. CONCLUSIONS As the size of the subscapularis tendon tear increased, the passive ranges of horizontal abduction and external rotation of the glenohumeral joint after repair decreased significantly. In shoulders with a subscapularis tendon tear, it is necessary to consider the reduction of external rotation depending on tear size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of the arthroscopic augmentation of the subscapularis tendon on shoulder instability and range of motion: A biomechanical study.

BACKGROUND Anterior shoulder dislocation is common. The treatment of recurrence with glenoid bone defect is still considered controversial. A new arthroscopic subscapularis augmentation has recently been described that functions to decrease the anterior translation of the humeral head. The purpose of the presented study was to examine the biomechanical effect on glenohumeral joint motion and st...

متن کامل

Interstitial Tear of the Subscapularis Tendon, Arthroscopic Findings and Technique of Repair

  Tears of the subscapularis tendon have been significantly recognized as a source of shoulder pain and dysfunction in the past decade, thanks to arthroscopic evaluation of the shoulder and biomechanical and anatomical studies of the tendon. Current classification of subscapularis tendon tear is based on insertion site of the tendon. Recently, a classification for non-insertional types of subsc...

متن کامل

Rotator Interval Lesion and Damaged Subscapularis Tendon Repair in a High School Baseball Player

In 2013, a 16-year-old baseball pitcher visited Nobuhara Hospital complaining of shoulder pain and limited range of motion in his throwing shoulder. High signal intensity in the rotator interval (RI) area (ball sign), injured subscapularis tendon, and damage to both the superior and middle glenohumeral ligaments were identified using magnetic resonance imaging (MRI). Repair of the RI lesion and...

متن کامل

The role of the rotator interval capsule in passive motion and stability of the shoulder.

The purpose of this study was to characterize the role of the capsule in the interval between the supraspinatus and subscapularis tendons with respect to glenohumeral motion, translation, and stability. We used a six-degrees-of-freedom position-sensor and a six-degrees-of-freedom force and torque-transducer to determine the glenohumoral rotations and translations that resulted from applied load...

متن کامل

Short term results of arthroscopic repair of subscapularis tendon tear

  Abstract   Background: Despite being the largest rotator cuff tendon of the shoulder, the   function and clinical relevance of subscapularis pathology has been largely ignored   in the literature. Although many studies have focused on subscapularis tears recently,   majority of them reported techniques for open repair. The advent of arthroscopy and   arthroscopic repair techniques has opened ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014