A new 3D monitor-based random-dot stereotest for children.
نویسندگان
چکیده
PURPOSE Objective testing for random-dot stereovision in preverbal children requires some type of dissociating glasses. Drawbacks of such methods are the alteration of natural visual conditions and sometimes nonacceptance of the glasses. For this reason, a new, natural method for random-dot stereopsis measurement was developed and tested. METHODS Random-dot circles (diameter 10 cm, crossed disparity of 0.34 degrees ) were generated on an autostereoscopic display and presented to 18 normal children (mean age, 5.1 +/- 1.1 years), 8 with anisometropic amblyopia (mean age, 4.9 +/- 1.3 years), 14 with infantile essential esotropia (mean age, 5.3 +/- 0.7 years), and 16 with primary microstrabismus (mean age, 5.2 +/- 1.4 years). While the position of the stimulus randomly changed among four possible locations, eye positions were recorded by infrared photo-oculography. If two or more consecutive saccades ends corresponded to the stimulus coordinates, a positive response was assumed. The results with the new test were compared with the ability to recognize the Lang I random-dot stereotest. RESULTS Twenty-four of 26 Lang I-positive children had positive responses (sensitivity of 92.3%), 29 of 30 Lang I-negative children had negative three-dimensional (3D) stimulus responses (specificity, 96.7%). The positive predictive value of the new test was 0.96 (95% CI, 0.79-0.99); the negative predictive value, 0.94 (95% CI, 0.78-0.99); and the overall accuracy, 0.95 (95% CI, 0.85-0.99). CONCLUSIONS This new 3D monitor-based test allows objective assessment of random-dot stereopsis in children older than 3 years.
منابع مشابه
[A new objective test for random-dot stereopsis in preverbal children].
BACKGROUND The Lang-Stereotest is at best half-objective in testing stereovision in preverbal children. We developed a new method which might objectively measure random-dot stereopsis in preverbal children. PATIENTS AND METHODS We project two separate random-dot images into the left and right eye using a 3D-monitor. If both eyes are perfectly aligned and random stereopsis is present, the chil...
متن کاملNew Stereoacuity Test Using a 3-Dimensional Display System in Children
The previously developed 3-dimensional (3D) display stereoacuity tests were validated only at distance. We developed a new stereoacuity test using a 3D display that works both at near and distance and evaluated its validity in children with and without strabismus. Sixty children (age range, 6 to 18 years) with variable ranges of stereoacuity were included. Side-by-side randot images of 4 differ...
متن کاملTestability of preschoolers on stereotests used to screen vision disorders.
OBJECTIVE The purpose was to determine whether preschool children aged 3 years 0 months through 3 years 6 months could be tested with the Random Dot E, Stereo Smile, and Randot Preschool stereoacuity tests, which are random dot stereotests marketed for use with preschoolers. METHODS A total of 118 children from five Vision In Preschoolers Study Clinical Centers participated. Strabismic childr...
متن کاملDevelopment of a Novel Stereoacuity Test Device Using a High-Resolution 3D Monitor
Purpose: To develop stereoacuity test using a high-resolution 3D monitor and examined the effects of the monitor on the measured stereoacuity. Methods: We conducted stereoacuity test using a high-resolution 3D monitor. This 3D monitor can show parallax of 27 s (crossed) at the minimum at measurement distance 40 cm, and circularly polarized glasses were used for binocular separation. Titmus ster...
متن کاملOverestimation of stereo thresholds by the TNO stereotest is not due to global stereopsis
PURPOSE It has been repeatedly shown that the TNO stereotest overestimates stereo threshold compared to other clinical stereotests. In the current study, we test whether this overestimation can be attributed to a distinction between 'global' (or 'cyclopean') and 'local' (feature or contour-based) stereopsis. METHODS We compared stereo thresholds of a global (TNO) and a local clinical stereote...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 47 11 شماره
صفحات -
تاریخ انتشار 2006