Heart–lung interactions during neurally adjusted ventilatory assist

نویسندگان

  • David Berger
  • Stefan Bloechlinger
  • Jukka Takala
  • Christer Sinderby
  • Lukas Brander
چکیده

INTRODUCTION Assist in unison to the patient's inspiratory neural effort and feedback-controlled limitation of lung distension with neurally adjusted ventilatory assist (NAVA) may reduce the negative effects of mechanical ventilation on right ventricular function. METHODS Heart-lung interaction was evaluated in 10 intubated patients with impaired cardiac function using esophageal balloons, pulmonary artery catheters and echocardiography. Adequate NAVA level identified by a titration procedure to breathing pattern (NAVAal), 50% NAVAal, and 200% NAVAal and adequate pressure support (PSVal, defined clinically), 50% PSVal, and 150% PSVal were implemented at constant positive end-expiratory pressure for 20 minutes each. RESULTS NAVAal was 3.1 ± 1.1cmH2O/μV and PSVal was 17 ± 2 cmH20. For all NAVA levels negative esophageal pressure deflections were observed during inspiration whereas this pattern was reversed during PSVal and PSVhigh. As compared to expiration, inspiratory right ventricular outflow tract velocity time integral (surrogating stroke volume) was 103 ± 4%, 109 ± 5%, and 100 ± 4% for NAVAlow, NAVAal, and NAVAhigh and 101 ± 3%, 89 ± 6%, and 83 ± 9% for PSVlow, PSVal, and PSVhigh, respectively (p < 0.001 level-mode interaction, ANOVA). Right ventricular systolic isovolumetric pressure increased from 11.0 ± 4.6 mmHg at PSVlow to 14.0 ± 4.6 mmHg at PSVhigh but remained unchanged (11.5 ± 4.7 mmHg (NAVAlow) and 10.8 ± 4.2 mmHg (NAVAhigh), level-mode interaction p = 0.005). Both indicate progressive right ventricular outflow impedance with increasing pressure support ventilation (PSV), but no change with increasing NAVA level. CONCLUSIONS Right ventricular performance is less impaired during NAVA compared to PSV as used in this study. Proposed mechanisms are preservation of cyclic intrathoracic pressure changes characteristic of spontaneous breathing and limitation of right-ventricular outflow impedance during inspiration, regardless of the NAVA level. TRIAL REGISTRATION Clinicaltrials.gov Identifier: NCT00647361, registered 19 March 2008.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neurally adjusted ventilatory assist

PURPOSE OF REVIEW Compared with the conventional forms of partial support, neurally adjusted ventilatory assist was repeatedly shown to improve patient-ventilator synchrony and reduce the risk of overassistance, while guaranteeing adequate inspiratory effort and gas exchange. A few animal studies also suggested the potential of neurally adjusted ventilatory assist in averting the risk of ventil...

متن کامل

Initiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran

Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...

متن کامل

0449. Surface EMG of extra-diaphragmatic muscles can assess muscle unloading during neurally adjusted ventilatory support

Introduction Neurally adjusted ventilatory assist (NAVA) is used to adapt mechanical ventilation to patient demand while unloading respiratory muscles. Titration methods are focused on sustained unloading of the diaphragm while maintaining a stable tidal volume [1]. It is hypothesized that the activity of accessory respiratory muscles can supply extra information about muscle unloading and pati...

متن کامل

Neurally adjusted ventilatory assist: a ventilation tool or a ventilation toy?

Mechanical ventilation has, since its introduction into clinical practice, undergone a major evolution from controlled ventilation to various modes of assisted ventilation. Neurally adjusted ventilatory assist (NAVA) is the newest development. The implementation of NAVA requires the introduction of a catheter to measure the electrical activity of the diaphragm (EA(di)). NAVA relies, opposite to...

متن کامل

Application of Selective Bronchial Intubation versus Neurally Adjusted Ventilatory Assist in the Management of Unilateral Pulmonary Interstitial Emphysema: An Illustrative Case and the Literature Review

In the treatment of left-sided pulmonary interstitial emphysema (PIE) in a 23-week neonate, we used two ventilatory strategies: selective bronchial intubation from day 10 to 15 and neurally adjusted ventilatory assist (NAVA) from day 18 to 26. We compared the effects and adverse effects of these two strategies. On selective bronchial intubation, desaturation was frequent. Fentanyl infusion was ...

متن کامل

0438. Effects of positive end-expiratory pressure (PEEP) on the pattern of breathing during neurally adjusted ventilatory assist. A pilot study in a mild ards porcine model

Introduction Spontaneous breathing during mechanical ventilation is still controversial. It is well known that incongruous patterns of mechanical ventilation can trigger or exacerbate lung injury. NAVA is a mode of mechanical ventilation that delivers ventilatory assist in proportion to the Electrical activity of the Diaphragm (EDi), which mirrors the performance of the whole respiratory system...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -