Quantitative detection of metabolites using matrix-assisted laser desorption/ionization mass spectrometry with 9-aminoacridine as the matrix.

نویسندگان

  • Seetharaman Vaidyanathan
  • Royston Goodacre
چکیده

Quantitative detection of metabolites is a highly desirable feature in metabolome analyses. Recently, the successful detection of multiple metabolites using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) in the negative ion mode employing 9-aminoacridine as the organic matrix was reported (Edwards JL, Kennedy RT. Anal. Chem. 2005; 77: 2201-2209). However, there is little information available on quantitative detection of multiple metabolites using MALDI-MS and in particular the influence changes in metabolite levels have on such detections. We investigated this aspect by spiking a synthetic metabolite cocktail (consisting of 39 metabolites including amino acids, organic acids and phospho-metabolites) with five representative metabolites at increasing concentrations, one metabolite at a time, and assessed the signals from replicate determinations. It was possible to detect quantitative changes in the spiked metabolites. Although analyte suppression was observed, it was possible to observe scenarios where the spiked metabolite had little or no influence on the quantitative detection of some metabolites. It appears that the mass spectral response of the metabolite is suppressed only when the spiked chemical species are relatively similar in chemical terms. This suggests that quantitation is possible in scenarios where changes in a specific metabolite or a class of metabolites are monitored following appropriate analyte separation strategies, and that careful interpretations must be made when using the technique for quantitative analysis in unbiased metabolomic approaches.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging Matrix Assisted Laser Desorption Ionization Mass Spectrometry: a technique to map plant metabolites within tissues at high spatial resolution.

Imaging Matrix Assisted Laser Desorption Ionization Mass Spectrometry provides a new and powerful tool to analyse the distribution of metabolites within plant tissues. The two matrices alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA) and 9-aminoacridine provide a useful combination that allows the measurement of amino acids, sugars, and phosphorylated metabolites. Results are presented showing t...

متن کامل

MALDI Efficiency of Metabolites Quantitatively Associated with their Structural Properties: A Quantitative Structure–Property Relationship (QSPR) Approach

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) experiments require a suitable match of the matrix and target compounds to achieve a selective and sensitive analysis. However, it is still difficult to predict which metabolites are ionizable with a given matrix and which factors lead to an efficient ionization. In the present study, we extracted structural properties of ...

متن کامل

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis of archaebacterial lipids in lyophilized membranes dry mixed with 9-aminoacridine

A method of direct lipid analysis by MALDI mass spectrometry in intact membranes, without prior extraction/separation steps, is described. The purple membrane isolated from the extremely halophilic archaeon Halobacterium salinarum was selected as model membrane. Lyophilized purple membranes were grinded with 9-aminoacridine as dry matrix and the powder mixture crushed in a mechanical die press ...

متن کامل

Mass spectrometric method incorporating enzymatic amplification for attomole-level analysis of target metabolites in biological samples.

We report a sensitive method for selective detection of target metabolites from the central metabolic pathway by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS), in which the MS signal is enhanced by up to three orders of magnitude in the course of in situ enzymatic amplification.

متن کامل

Reduced graphene oxide films used as matrix of MALDI-TOF-MS for detection of octachlorodibenzo-p-dioxin.

A reduced graphene oxide (rGO) film was used as the matrix in the matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy (MALDI-TOF-MS) for the detection of octachlorodibenzo-p-dioxin (OCDD) with a detection weight as low as 500 pg.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 21 13  شماره 

صفحات  -

تاریخ انتشار 2007