Accuracy of calibrated-loop transfer.
نویسندگان
چکیده
The accuracy of the 0.001-ml calibrated platinum loop was tested by two methods: visible absorption spectroscopy and weight determinations. By both methods it was demonstrated that the volume of the loop delivery is related to the angle at which the loop is withdrawn from the solution being sampled and the diameter of the container, provided that the volume in the container is adequate to cover the loop. Vertical sampling from small-diameter containers (less than or equal to 7-mm inside diameter) delivered approximately 50% of 0.001 ml, and sampling at a 45 degree angle from larger containers (greater than or equal to 22-mm inside diameter) gave a delivery volume of greater than 150% of 0.001 ml, resulting in a threefold difference in the amount delivered and an error rate of +/- 50%.
منابع مشابه
MICROSURGICA.L TREATMENT OF UPPER ESOPHAGEAL CARCINOMA (FREE JEJUNAL LOOP TRANSFER)
There are unfortunately a relatively large number of cases of esophageal cancer in Iran as well as other countries, and one of the most difficult problems facing surgeons is the reconstruction of the esophagus and restoration of its function after excision of the tumor. From 1978 to 1987,20 patients (16 male, 4 female) ranging in age from 22 to 68 years were surgically treated for squamous...
متن کاملComparison of Different Loop Bioreactors Based on Hydrodynamic Characteristics, Mass Transfer, Energy Consumption and Biomass Production from Natural Gas
The performance of a forced-liquid Vertical Tubular Loop Bioreactor (VTLB), a forced-liquid Horizontal Tubular Loop Bioreactor (HTLB) and a gas-induced External Airlift Loop Bioreactor (EALB) were compared for production of biomass from natural gas. Hydrodynamic characteristics and mass transfer coefficients were determined as functions of design parameters, physical properties of gases as ...
متن کاملA New Method for Time-Delay Compensation in Control Systems
In this paper a new method is introduced and investigated for removing the destabilizing effects of time-delay parameter in control loops. The concept of the method is taken from the knowledge concerning the dynamic behaviour of irrational transfer functions (Ir-TF), which is discussed and investigated elswhere in frequency response domain and is explained briefly here. Ir-TFs, which are we...
متن کاملImprovement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...
متن کاملFinal Analytical Comparison of Aggregate and Disaggregate Mode Choice Models Transferability
Transportation models as tools for transportation planning are critical to such related decisions. Considering the high cost of calibrating and validating such models, effective alternatives are highly sought for; one such alternative being the use of models calibrated for other cities. This calls for transferability analysis which has not been the subject of many researches. Due to criticalit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 18 1 شماره
صفحات -
تاریخ انتشار 1983