New developments in reprocessing semicritical items.

نویسندگان

  • William A Rutala
  • David J Weber
چکیده

Semicritical medical devices are defined as items that come into contact with mucous membranes or nonintact skin (eg, gastrointestinal endoscopes). Such medical devices require minimally high-level disinfection. Because many of these items are temperature sensitive, low-temperature chemical methods must be used rather than steam sterilization. Strict adherence to current guidelines is required because more outbreaks have been linked to inadequately cleaned or disinfected endoscopes undergoing high-level disinfection than any other medical device.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reprocessing semicritical items: Current issues and new technologies.

Semicritical medical devices are defined as items that come into contact with mucous membranes or nonintact skin (eg, gastrointestinal endoscopes, endocavitary probes). Such medical devices minimally require high-level disinfection. Because many of these items are temperature sensitive, low-temperature chemical methods are usually used rather than steam sterilization. Strict adherence to curren...

متن کامل

Disinfection of endoscopes: review of new chemical sterilants used for high-level disinfection.

Chemical sterilants are used to high-level disinfect heat-sensitive semicritical items such as endoscopes. Most endoscopes have been reprocessed between each patient use with glutaraldehyde (>2%) or the Steris System 1. Several new chemical sterilants have been developed recently, including 7.5% hydrogen peroxide, 0.08% peracetic acid plus 1.0% hydrogen peroxide, and 0.55% orthophthalaldehyde. ...

متن کامل

Disinfection and sterilization: an overview.

All invasive procedures involve contact by a medical device or surgical instrument with a patient's sterile tissue or mucous membranes. The level of disinfection or sterilization is dependent on the intended use of the object: critical (items that contact sterile tissue such as surgical instruments), semicritical (items that contact mucous membrane such as endoscopes), and noncritical (devices ...

متن کامل

Origins of emotional consciousness.

While the field of emotions research has benefited from new developments in neuroscience, many theoretical questions remain unsolved. We propose that integrating our iterative reprocessing (IR) framework with the passive frame theory (PFT) may help unify competing theoretical perspectives of emotion. Specifically, we propose that PFT and the IR framework offer a point of origin for emotional ex...

متن کامل

Comparison on the Efficacy of Disinfectants Used in Automated Endoscope Reprocessors: PHMB-DBAC versus Orthophthalaldehyde

BACKGROUND/AIMS Since endoscopes are reusable apparatus classified as semicritical item, thorough reprocessing to achieve high-level disinfection is of utmost importance to prevent spread of infection. To improve disinfection efficacy and safety, disinfectants and endoscope reprocessors are continuously evolving. This study aimed to compare the efficacy of the combination of polyhexamethylenebi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of infection control

دوره 41 5 Suppl  شماره 

صفحات  -

تاریخ انتشار 2013