Reclaiming the Periphery: Automated Kinetic Perimetry for Measuring Peripheral Visual Fields in Patients With Glaucoma.
نویسندگان
چکیده
Purpose Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Methods Thirty patients with glaucoma (median age 68, range 59-83 years; median Mean Deviation -8.0, range -16.3-0.1 dB) performed AKP and static automated perimetry (SAP) (German Adaptive Threshold Estimation strategy, 24-2 test). Automated kinetic perimetry consisted of a fully automated measurement of a single isopter (III.1.e). Central and peripheral visual fields were measured twice on the same day. Results Peripheral and central visual fields were only moderately related (Spearman's ρ, 0.51). Approximately 90% of test-retest differences in mean isopter radius were < ±4 deg. Relative to the range of measurements in this sample, the retest variability of AKP was similar to that of SAP. Conclusions Patients with similar central visual field loss can have strikingly different peripheral visual fields, and therefore measuring the peripheral visual field may add clinically valuable information.
منابع مشابه
Automated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.
OBJECTIVES To create a fully automated, combined perimetry program consisting of a static examination and a kinetic examination, and to compare the results of this test with standard static and kinetic visual fields (VFs). METHODS Fifty-six patients (74 eyes) undergoing neuro-ophthalmic or glaucoma evaluation who had standard static or kinetic perimetry examinations underwent the combined per...
متن کاملInvestigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملTopography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.
BACKGROUND Traquair described the topography of visual field sensitivity as a "hill" or "island" of vision. Achromatic automated perimetry (AAP) demonstrates this shape of the visual field in photopic conditions. Techniques claimed to target the magnocellular pathway (frequency doubling perimetry, FDP) and those using a stimulus targeting the koniocellular pathway (short wavelength (or blue on ...
متن کاملComparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...
متن کاملStructure–Function Relationship in Glaucoma Patients With Parafoveal Versus Peripheral Nasal Scotoma
PURPOSE We evaluated whether the structure-function relationship in glaucoma patients with parafoveal scotoma or peripheral scotoma differs with the use of frequency doubling technology (FDT) or short-wavelength automated perimetry (SWAP) compared to standard automated perimetry (SAP). METHODS Glaucoma patients with isolated parafoveal scotoma (PFS) within the central 10° of fixation in 1 hem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 58 2 شماره
صفحات -
تاریخ انتشار 2017