Breath acetone to monitor life style interventions in field conditions: an exploratory study.
نویسندگان
چکیده
OBJECTIVE To assess whether breath acetone concentration can be used to monitor the effects of a prolonged physical activity on whole body lipolysis and hepatic ketogenesis in field conditions. METHODS Twenty-three non-diabetic, 11 type 1 diabetic, and 17 type 2 diabetic subjects provided breath and blood samples for this study. Samples were collected during the International Four Days Marches, in the Netherlands. For each participant, breath acetone concentration was measured using proton transfer reaction ion trap mass spectrometry, before and after a 30-50 km walk on four consecutive days. Blood non-esterified free fatty acid (NEFA), beta-hydroxybutyrate (BOHB), and glucose concentrations were measured after walking. RESULTS Breath acetone concentration was significantly higher after than before walking, and was positively correlated with blood NEFA and BOHB concentrations. The effect of walking on breath acetone concentration was repeatedly observed on all four consecutive days. Breath acetone concentrations were higher in type 1 diabetic subjects and lower in type 2 diabetic subjects than in control subjects. CONCLUSIONS Breath acetone can be used to monitor hepatic ketogenesis during walking under field conditions. It may, therefore, provide real-time information on fat burning, which may be of use for monitoring the lifestyle interventions.
منابع مشابه
DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کاملNon-(13)CO2 targeted breath tests: a feasibility study.
Breath tests allow a non-invasive and fast diagnostic of different specific enzymes' phenotypic functionality. Over the last decade several 13C-breath tests were successfully tested, with the (13)C-urea breath test being approved by the US Food and Drug Administration (FDA) and the European Medicines Agency (EMA). The use of other targets than labeled (13)CO2 in exhaled breath offers additional...
متن کاملBreath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps Running head: Breath acetone in type 1 diabetes
Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry (SIFT-MS) to monitor the breath of 8 patients with type...
متن کاملBreath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps.
Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry to monitor the breath of eight patients with type 1 dia...
متن کاملMonitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: an observational study
BACKGROUND Volatile breath biomarkers provide a non-invasive window to observe physiological and pathological processes in the body. This study was intended to assess the impact of heart surgery with extracorporeal circulation (ECC) onto breath biomarker profiles. Special attention was attributed to oxidative or metabolic stress during surgery and extracorporeal circulation, which can cause org...