Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging
نویسندگان
چکیده
University of Texas MD Anderson Cancer Center, USA It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/ MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.
منابع مشابه
PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.
PURPOSE To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager. MATERIALS AND METHODS All animal experiments were performed in accordance with the University of Tübingen guidelines and the German law for the protection of animals. A compact lutetium oxyorthosilicat...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملCurrent Trends in PET and Combined (PET/CT and PET/MR) Systems Design.
Molecular imaging using high-resolution PET instrumentation has a pivotal role in basic and clinical research. The development of optimized detection geometries combined with high-performance detector technologies and compact designs of PET tomographs has become the goal of active research groups in academic and corporate settings. More recently, the introduction of dual-modality PET/CT imaging...
متن کاملMR - PET : Combining Function , Anatomy , and More Markus Schwaiger
It is widely accepted that coregistration of anatomical information improves the diagnostic value of functional imaging. At the moment, this is reflected in the success of hybrid scanners using PET and CT imaging. But the combination of PET and MR imaging may also offer advantages, such as higher soft tissue contrast in the MR anatomical images, real simultaneous acquisition, and minimum radiat...
متن کاملImprovement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.
UNLABELLED Quantitative PET imaging relies on accurate attenuation correction. Recently, there has been growing interest in combining state-of-the-art PET systems with MR imaging in a sequential or fully integrated setup. As CT becomes unavailable for these systems, an alternative approach to the CT-based reconstruction of attenuation coefficients (μ values) at 511 keV must be found. Deriving μ...