An Inverted-Pendulum Thrust Stand for High-Power Electric Thrusters∗

نویسندگان

  • A. D. Kodys
  • R. Murray
  • L. Cassady
  • E. Y. Choueiri
چکیده

The inverted-pendulum method of thrust measurement for high-power electric thrusters is described analytically and experimentally. Two sources of uncertainty in the thrust measurements are investigated: those due to changes in the sensitivity of the inverted pendulum and those due to tare forces resulting from thermal stresses and electromagnetic forces acting on the flexural elements. An idealized analytical model shows that changes in sensitivity occur due to changes in the mass loading of the inverted pendulum and the temperature of the flexure elements. The sensitivity can be increased only at the expense of more stringent requirements on mass loading and thermal control. The results of the model are validated with measurements made using a carefully calibrated inverted pendulum thrust stand having several advantageous design features including gallium pots for current conduction, an optical two-axis displacement sensor, and careful consideration of flexure shape and cooling requirements. The sensitivity is shown to be constant over a wide range of operating conditions. Measurements show that thermal drifts of the stand are linear on the time scale of the thrust measurements and are less than 0.6% of the expected thrust. The thrust stand operation was demonstrated during experiments with a 30-kW lithium-fed applied-field magnetoplasmadynamic thruster. Under nominal conditions ( 400 A, 0.1 T, 17.5 mg/s) the thermal and electromagnetic tare forces were measured at less than 9% of the thrust and the total thrust uncertainty at ≤ 10% of the thrust.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-power, null-type, inverted pendulum thrust stand.

This article presents the theory and operation of a null-type, inverted pendulum thrust stand. The thrust stand design supports thrusters having a total mass up to 250 kg and measures thrust over a range of 1 mN to 5 N. The design uses a conventional inverted pendulum to increase sensitivity, coupled with a null-type feature to eliminate thrust alignment error due to deflection of thrust. The t...

متن کامل

Technique to Collimate Ions in a Hall-Effect Thruster Discharge Chamber

High thrust-to-power ratio on Hall-effect thrusters allows for more efficient thrust generation and better overall performance. It allows Hall-effect thrusters to perform more thrust-intensive maneuvers such as orbit raising, thus saving the mass of a second engine purely for those maneuvers. This paper presents the initial performance measurements of aHall-effect thruster using in-channel elec...

متن کامل

Non-contact thrust stand calibration method for repetitively pulsed electric thrusters.

A thrust stand calibration technique for use in testing repetitively pulsed electric thrusters for in-space propulsion has been developed and tested using a modified hanging pendulum thrust stand. In the implementation of this technique, current pulses are applied to a solenoid to produce a pulsed magnetic field that acts against a permanent magnet mounted to the thrust stand pendulum arm. The ...

متن کامل

Preliminary Pulsed MPD Thruster Performance

A thrust stand was modified, and a primary calibration technique was developed to evaluate the performance of applied-field pulsed magnetoplasmadynamic thrusters (MPDTs) for 10 kW class solar electric orbit transfer vehicle (SEOTV) missions. The NASA Lewis Research Center (LeRC) 30 kW thrust stand was modified to accept high current pulses delivered to the MPDT. A pendulum system was developed ...

متن کامل

PPT Thrust Stand

A torsional-type thrust stand has been designed and built to test Pulsed Plasma Thrusters (PPTs) in both single shot and repetitive operatingmodes. Using this stand, momentum per pulse was determined strictly as a function of thrust stand deflection, spring stiffness, and natural frequency. No empirical corrections were required. The accuracy of the method was verified using a swinging impact p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006