Evaluation of loop-mediated isothermal amplification method for detecting enterotoxin A gene of Staphylococcus aureus in pork.

نویسندگان

  • Theeranan Suwanampai
  • Kobchai Pattaragulvanit
  • Preprame Pattanamahakul
  • Orasa Sutheinkul
  • Kazuhisa Okada
  • Takeshi Honda
  • Jiraporn Thaniyavarn
چکیده

Staphylococcus aureus is an important food-borne pathogen of humans due to ingestion of food containing enterotoxigenic strains. We evaluated the detection of S. aureus enterotoxin A gene (sea) using a loop-mediated isothermal DNA amplification (LAMP) method. Specificity of LAMP method was comparable to that of conventional PCR. Both methods correctly identified sea and did not detect 14 other non-Staphylococcus strains. Limit of detections of LAMP assay for direct detection of S. aureus was 10(4) cfu/ml while that of PCR was 10(3) cfu/ml. Both methods were employed for the detection of S. aureus spiked pork samples to assess their sensitivity. LAMP method was able to detect a minimum of 10(3) cfu/g while PCR 10(4) cfu/g of pork sample following incubation in tryptic soy broth for 6 hours. The LAMP assay allows a one-step identification of gene of interest without any specialized equipment and requires less time than conventional PCR, thus suggesting that the LAMP technique might be an appropriate alternative diagnostic method for detecting enterotoxin A gene of S. aureus in food sample.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loop-Mediated Isothermal Amplification Assay for the Rapid Detection of Staphylococcus aureus

Staphylococcus aureus, including methicillin-resistant S. aureus (MRSA), is an important human pathogen that produces a variety of toxins and causes a wide range of infections, including soft-tissue infections, bacteremia, and staphylococcal food poisoning. A loop-mediated isothermal amplification (LAMP) assay targeting the arcC gene of S. aureus was developed and evaluated with 119 S. aureus a...

متن کامل

تشخیص و افتراق سریع فاسیولا هپاتیکا و فاسیولا ژیگانتیکا با استفاده از روش loop-mediated Isothermal Amplification

Background and purpose: Fasciola hepatica and Fasciola gigantica are common liver flukes which affect both human and livestock worldwide. In this study we evaluated the loop-mediated isothermal amplification (LAMP) assay for detection and discrimination of Fasciola species. Materials and methods: Fifty adults of Fasciola worms were isolated from sheep and cattle liver form abattoirs in Mazand...

متن کامل

Molecular Detection of Staphylococcus aureus Enterotoxin A and B Genes in Clinical Samples from Patients Referred to Health Centers in Zahedan City

Background: In this study we aimed at detecting the enterotoxin A and B gene of S. aureus in clinical samples of patients attending health centers in Zahedan using molecular methods. Materials and Methods: A cross-sectional study was carried out in which 40 samples of S. aureus were obtained from patients in a hospital in Zahedan, Iran. Following the biochemical tests, Identifications were c...

متن کامل

NOTE Bacteriology Improved rapid and efficient method for Staphylococcus aureus DNA extraction from milk for identification of mastitis pathogens

A rapid and efficient DNA extraction method was developed for detecting mastitis pathogens in milk. The first critical step involved cell wall disruption by bead-beating, as physical disruption using beads was more effective for DNA extraction from Gram-positive bacteria, such as Staphylococcus aureus, than enzymatic disruption using proteinase K. The second critical step involves the use of ac...

متن کامل

Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis

To develop a rapid detection method of Staphylococcus aureus using loop-mediated isothermal amplification (LAMP), four specific primers were designed according to six distinct sequences of the nuc gene. In addition, the specificity and sensitivity of LAMP were verified and compared with those of PCR. Results showed that the LAMP reaction was completed within 45 min at 62.5°C, and ladder bands w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Southeast Asian journal of tropical medicine and public health

دوره 42 6  شماره 

صفحات  -