BACKGROUND A lumbar pedicular dynamic stabilization system (LPDSS) is an alternative to fusion for treatment of degenerative disc disease (DDD). In this study, clinical and radiological results of one LPDSS (Saphinaz, Medikon AS, Turkey) were compared with results of rigid fixation after two-year follow-up. METHODS All patients had anteroposterior and lateral standing x-rays of the lumbar spine preoperatively and at 3 months, 12 months and 24 months after surgery. Lordosis of the lumbar spine, segmental lordosis and ratio of the height of the intervertebral disc spaces (IVS) measured preoperatively and at 3 months, 12 months and 24 months after surgery. All patients underwent MRI and/or CT preoperatively, 3months, 12 months and 24 months postoperatively. The ratio of intervertebral disc space to vertebral body height (IVS) and segmental and lumbar lordosis were evaluated preoperatively and postoperatively. Pain scores were evaluated via Visual Analog Scale (VAS) and Oswestry Disability Index (ODI) preoperatively and postoperatively. RESULTS In both groups, the VAS and ODI scores decreased significantly from preoperatively to postoperatively. There was no difference in the scores between groups except that a lower VAS and ODI scores were observed after 3 months in the LPDSS group. In both groups, the IVS ratio remained unchanged between preoperative and postoperative conditions. The lumbar and segmental lordotic angles decreased insignificantly to preoperative levels in the months following surgery. CONCLUSIONS Patients with LPDSS had equivalent relief of pain and maintenance of sagittal balance to patients with standard rigid screw-rod fixation. LPDSS appears to be a good alternative to rigid fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience

INTRODUCTION The development of adjacent-segment disease is a recognized consequence of lumbar fusion surgery. Posterior dynamic stabilization, or motion preservation, techniques have been developed which theoretically decrease stress on adjacent segments following fusion. This study presents the experience of using a hybrid dynamic stabilization and fusion construct for degenerative lumbar spi...

متن کامل

Does the Addition of a Dynamic Pedicle Screw to a Fusion Segment Prevent Adjacent Segment Pathology in the Lumbar Spine?

Study Design Retrospective clinical cohort study. Purpose To investigate whether the combined use of dynamic pedicle screws and polyaxial pedicle screws was effective on adjacent segment pathology (ASP). Overview of Literature Various screw and rod models have been recently developed for preventing adjacent segment disease, and hybrid systems have been described along with posterior instrum...

متن کامل

Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases: clinical experience with a 2-year follow-up

BACKGROUND Polyetheretherketone (PEEK) rod system is a novel pedicle-based dynamic stabilization system. This study evaluated clinical and radiographic outcomes of non-fusion surgery by PEEK rod systems for treatment of degenerative lumbar diseases with a 2-year follow-up. METHODS From February 2012 to October 2012, 38 patients who underwent non-fusion surgery using PEEK rod systems were incl...

متن کامل

Dynamic Stabilization for Degenerative Spondylolisthesis and Lumbar Spinal Instability

Lumbar interbody fusion is a widely accepted surgical procedure for patients with lumbar degenerative spondylolisthesis and lumbar spinal instability in the active age group. However, in elderly patients, it is often questionable whether it is truly necessary to construct rigid fixation for a short period of time. In recent years, we have been occasionally performing posterior dynamic stabiliza...

متن کامل

Comparison of the Load-sharing Characteristics between Pedicle-based Composite and Rigid Rod Devices

1. Introduction Adjacent segment degeneration (ASD) has been reported as the one of late serious complication after spinal fusion surgery [1-3]. Presumably, the immediate rigidity produced by instrumentation causes more stress leading to accelerated degeneration at adjacent levels [2]. Many previous studies have been corroborated a trend toward earlier development of ASD with instrumentation as...