Direct Comparison of Virtual-Histology Intravascular Ultrasound and Optical Coherence Tomography Imaging for Identification of Thin-Cap Fibroatheroma
نویسندگان
چکیده
BACKGROUND Although rupture of thin-cap fibroatheroma (TCFA) underlies most myocardial infarctions, reliable TCFA identification remains challenging. Virtual-histology intravascular ultrasound (VH-IVUS) and optical coherence tomography (OCT) can assess tissue composition and classify plaques. However, direct comparisons between VH-IVUS and OCT are lacking and it remains unknown whether combining these modalities improves TCFA identification. METHODS AND RESULTS Two hundred fifty-eight regions-of-interest were obtained from autopsied human hearts, with plaque composition and classification assessed by histology and compared with coregistered ex vivo VH-IVUS and OCT. Sixty-seven regions-of-interest were classified as fibroatheroma on histology, with 22 meeting criteria for TCFA. On VH-IVUS, plaque (10.91±4.82 versus 8.42±4.57 mm(2); P=0.01) and necrotic core areas (1.59±0.99 versus 1.03±0.85 mm(2); P=0.02) were increased in TCFA versus other fibroatheroma. On OCT, although minimal fibrous cap thickness was similar (71.8±44.1 μm versus 72.6±32.4; P=0.30), the number of continuous frames with fibrous cap thickness ≤85 μm was higher in TCFA (6.5 [1.75-11.0] versus 2.0 [0.0-7.0]; P=0.03). Maximum lipid arc on OCT was an excellent discriminator of fibroatheroma (area under the curve, 0.92; 95% confidence interval, 0.87-0.97) and TCFA (area under the curve, 0.86; 95% confidence interval, 0.81-0.92), with lipid arc ≥80° the optimal cut-off value. Using existing criteria, the sensitivity, specificity, and diagnostic accuracy for TCFA identification was 63.6%, 78.1%, and 76.5% for VH-IVUS and 72.7%, 79.8%, and 79.0% for OCT. Combining VH-defined fibroatheroma and fibrous cap thickness ≤85 μm over 3 continuous frames improved TCFA identification, with diagnostic accuracy of 89.0%. CONCLUSIONS Both VH-IVUS and OCT can reliably identify TCFA, although OCT accuracy may be improved using lipid arc ≥80° and fibrous cap thickness ≤85 μm over 3 continuous frames. Combined VH-IVUS/OCT imaging markedly improved TCFA identification.
منابع مشابه
Quantifying Plaque Burden and Morphology Using Coronary Computed Tomography Angiography to Predict Coronary Physiology: Helpful…But Is It Sufficient?
Direct Comparison of Virtual-Histology Intravascular Ultrasound and Optical Coherence Tomography Imaging for Identification of Thin-Cap Fibroatheroma Adam J. Brown, MD; Daniel R. Obaid, MD, PhD; Charis Costopoulos, MD; Richard A. Parker, MSc; Patrick A. Calvert, MD, PhD; Zhongzhao Teng, PhD; Stephen P. Hoole, MD; Nick E.J. West, MD; Martin Goddard, MD; Martin R. Bennett, MD, PhD · · · · · · · ·...
متن کاملOptical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation.
BACKGROUND We report findings from optical coherence tomography (OCT) of in-stent neoatherosclerosis as a cause of drug-eluting stent (DES) failure. METHODS AND RESULTS Optical coherence tomography and grayscale and virtual histology intravascular ultrasound were performed in 50 patients (30 stable, 20 unstable angina) with 50 DES in-stent restenosis lesions and intimal hyperplasia >50% of st...
متن کاملCharacterization of coronary plaques with combined use of intravascular ultrasound, virtual histology and optical coherence tomography
According to post-mortem studies, luminal thrombosis occurs from plaque rupture, erosion and calcified nodules. In vivo studies have found thin cap fibroatheroma (TCFA) as the main vulnerable lesion, prone to rupture. Few data about other post-mortem lesions have been reported in vivo. Our main objective is to characterize in vivo the coronary plaques with intravascular ultrasound-virtual histo...
متن کاملDiagnosis of Thin-Capped Fibroatheromas in Intravascular Optical Coherence Tomography Images
Plaque rupture is responsible for up to 75% of acute coronary syndromes and is an important mechanism for atherosclerotic disease progression. Plaque rupture is most often preceded by the development of a thin-capped fibroatheroma (TCFA), the most common type of vulnerable plaque. Intravascular optical coherence tomography (IVOCT) is the only coronary imaging modality available clinically that ...
متن کاملElevated levels of systemic pentraxin 3 are associated with thin-cap fibroatheroma in coronary culprit lesions: assessment by optical coherence tomography and intravascular ultrasound.
OBJECTIVES This study sought to determine whether systemic levels of pentraxin 3 (PTX3), a novel inflammatory marker, are associated with thin-cap fibroatheroma (TCFA). BACKGROUND Biomarkers predicting the presence of TCFA in vivo have not been established. METHODS We evaluated 75 patients (stable angina pectoris, n = 47; acute coronary syndrome, n = 28) with de novo culprit lesions who wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -