An Evaluation of Commercial Fluorescent Bead-Based Luminex Cytokine Assays

نویسندگان

  • Joel Fleury Djoba Siawaya
  • Teri Roberts
  • Chantal Babb
  • Gillian Black
  • Hawa Jande Golakai
  • Kim Stanley
  • Nchinya Bennedict Bapela
  • Eileen Hoal
  • Shreemanta Parida
  • Paul van Helden
  • Gerhard Walzl
چکیده

The recent introduction of fluorescent bead-based technology, allowing the measurement of multiples analytes in a single 25-50 microl sample has revolutionized the study of cytokine responses. However, such multiplex approaches may compromise the ability of these assays to accurately measure actual cytokine levels. This study evaluates the performance of three commercially available multiplex cytokine fluorescent bead-based immunoassays (Bio-Rad's Cytokine 17-plex kit; LINCO Inc's 29-plex kit; and RnD System's Fluorokine-Multi Analyte Profiling (MAP) base kit A and B). The LINCO Inc kit was found to be the most sensitive assay for measuring concentrations of multiple recombinant cytokines in samples that had been spiked with serial dilutions of the standard provided by the manufacturer, followed respectively by the RnD Fluorokine-(MAP) and Bio-Rad 17-plex kits. A positive correlation was found in the levels of IFN-gamma measured in antigen stimulated whole blood culture supernatants by the LINCO Inc 29-plex, RnD Fluorokine-(MAP) and RnD system IFN-gamma Quantikine ELISA kits across a panel of controls and stimulated samples. Researchers should take the limitation of such multiplexed assays into account when planning experiments and the most appropriate use for these tests may currently be as screening tools for the selection of promising markers for analysis by more sensitive techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Luminex® Assays High-throughput Multiplex Bead Based Assays

Panomics has an aggressive program for the development of a broad range of assays for the Luminex platform and similar instruments based on the xMAP technology. Currently we have hundreds of RNA targets available in 3–30 plex assays using our using our QuantiGene Plex Reagent Systems, with new targets being added weekly. Our Procarta® Human, Mouse and Rat Assays can quantitatively measure cytok...

متن کامل

Development of Ss-NIE-1 Recombinant Antigen Based Assays for Immunodiagnosis of Strongyloidiasis

Strongyloides stercoralis is a widely distributed parasite that infects 30 to 100 million people worldwide. In the United States strongyloidiasis is recognized as an important infection in immigrants and refugees. Public health and commercial reference laboratories need a simple and reliable method for diagnosis of strongyloidiasis to identify and treat cases and to prevent transmission. The re...

متن کامل

Establishment and evaluation of a bead-based luminex assay allowing simultaneous quantification of equine IL-12 and IFN-γ.

BACKGROUND/AIM Interleukin-12 (IL-12) and interferon gamma (IFN-γ) are key cytokines in immunemediated equine melanoma therapy. Currently, a method for accurate simultaneous quantification of these equine cytokines is lacking. Therefore, we sought to establish an assay that allows for accurate and simultaneous quantification of equine IL-12 (eIL-12) and IFN-γ (eIFN-γ). MATERIALS AND METHODS S...

متن کامل

Development of a bead-based multiplex assay for simultaneous quantification of cytokines in horses.

The detection and quantification of equine cytokines has been hampered by the lack of antibodies for many years. With the development of antibody pairs for equine cytokines during the past years, the quantification of these essential regulators of the immune response became possible. After being successfully tested by enzyme-linked immunosorbent assays (ELISA), three of these anti-cytokine reag...

متن کامل

Overview of Luminex Assay Performance

Luminex Assay Design and Methods. Luminex assays use antibody-conjugated bead sets to detect analytes in a multiplexed sandwich immunoassay format. Each bead in the set is identified by a unique content of two addressing dyes, with a third dye used to read out binding of the analyte via a biotin-conjugated antibody and streptavidin-conjugated second step detector. Data is acquired on a dedicate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • PLoS ONE

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2008