Accelerated three-dimensional cine phase contrast imaging using randomly undersampled echo planar imaging with compressed sensing reconstruction.

نویسندگان

  • Tamer A Basha
  • Mehmet Akçakaya
  • Beth Goddu
  • Sophie Berg
  • Reza Nezafat
چکیده

The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction

Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...

متن کامل

Accelerated Proton Echo-Planar Spectroscopic Imaging Using Parallel Imaging and Compressed Sensing

INTRODUCTION: Proton Echo-Planar Spectroscopic Imaging (PEPSI) provides fast spatial-spectral encoding and has been demonstrated to map a variety of metabolites in the human brain [1,2]. Further acceleration in PEPSI can be accomplished by using parallel imaging along the phaseencoding dimension(s) [3,4]. However, the acceleration is limited by the relatively low SNR of the metabolites and g-fa...

متن کامل

Accelerated Simultaneous Multi-slice Cardiac Cine Imaging Using a Combination of CAIPIRINHA and Compressed Sensing

images of the two simultaneously excited slices. Displayed are (a) the conventional reconstruction of the CAIPIRINHA acquisition using GRAPPA and (b) the reconstruction of the incoherently undersampled CAIPIRINHA acquisition using the proposed combination of Compressed Sensing and GRAPPA. (c) Difference between a) and b) magnified by a factor of 10. Accelerated Simultaneous Multi-slice Cardiac ...

متن کامل

Compressed sensing reconstruction for undersampled breath-hold radial cine imaging with auxiliary free-breathing data.

PURPOSE To improve compressed sensing (CS) reconstruction of accelerated breath-hold (BH) radial cine magnetic resonance imaging (MRI) by exploiting auxiliary data acquired between different BHs. MATERIALS AND METHODS Cardiac function is usually assessed using segmented cine acquisitions over multiple BHs to cover the entire left ventricle (LV). Subjects are given a resting period between adj...

متن کامل

Turbo fast three-dimensional carotid artery black-blood MRI by combining three-dimensional MERGE sequence with compressed sensing.

PURPOSE In this study, we sought to investigate the feasibility of turbo fast three-dimensional (3D) black-blood imaging by combining a 3D motion-sensitizing driven equilibrium rapid gradient echo sequence with compressed sensing. METHODS A pseudo-centric phase encoding order was developed for compressed sensing-3D motion-sensitizing driven equilibrium rapid gradient echo to suppress flow sig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NMR in biomedicine

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2015