Atrial tachyarrhythmia burden modelling by some electrophysiological parameters in pacemaker-recipient patients with Brady-Tachy syndrome.

نویسندگان

  • Paolo Azzolini
  • Giuseppe Critelli
  • Vito De Giorgi
  • Giovanni B Del Giudice
  • Gianfranco Ibba
  • Donato Melissano
  • Alberto Scaccia
  • Andrea Puglisi
چکیده

AIMS (1) To correlate atrial tachyarrhythmia (AT) burden of pacemaker-recipient Brady-Tachy syndrome (BTS) patients with a number of diagnostics-derived parameters after 1 month of DDD pacing; (2) to asses whether the activation of atrial overdrive or conventional rate-responsive pacing may affect relevant variables and their correlation. METHODS AND RESULTS After 1 month of DDD pacing, rate-responsive function or persistent atrial overdrive was randomly activated for 3 months, in 92 BTS patients. Some pacemaker diagnostics parameters collected at 1- and 4-month follow-ups were included in multiple linear regression models, whose dependent variable was the Log transformation of AT burden and compared. With 1-month data, the only variables significantly correlating with Log AT burden were average (with a regression coefficient estimate of -0.07, P=0.02) and standard deviation (0.10, P=0.007) of atrial rate, mean premature atrial contraction (PAC) coupling interval (CI) (-0.005, P=0.001), frequency of PACs with CI<500 ms (1.30, P<10(-6)). Atrial pacing percentage (APP) and ventricular pacing percentage (VPP), PACs with CI>500 ms did not significantly correlate. Four-month data largely confirmed these results, except that in DDDR atrial rate average and standard deviation no longer correlated. Overdrive significantly increased APP and reduced PACs with CI>500 ms. CONCLUSION AT burden showed significant dependence in DDD and during overdrive on atrial rate average and standard deviation. Highly premature PACs always significantly correlated with AT burden. Though increasing APP, which unexpectedly never correlated, overdrive could only reduce less premature PACs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Closed-Loop Stimulation, overdrive pacing, DDDR pacing mode on atrial tachyarrhythmia burden in Brady-Tachy Syndrome. A randomized study.

AIMS Atrial overdrive pacing algorithms increase Atrial Pacing Percentage (APP) to reduce Atrial Tachyarrhythmia (AT) recurrences in patients with Brady-Tachy Syndrome (BTS). This study aimed to compare AT burden and APP in BTS patients treated with conventional DDDR pacing, DDD+ overdrive or Closed-Loop Stimulation (CLS). METHODS AND RESULTS One hundred and forty-nine BTS patients were inclu...

متن کامل

Arterial thromboembolism in patients with sick sinus syndrome: prediction from pacing mode, atrial fibrillation, and echocardiographic findings.

OBJECTIVE To evaluate whether thromboembolism in sick sinus syndrome can be predicted by pacing mode, atrial fibrillation, or echocardiographic findings. METHODS Patients were randomised to single chamber atrial (n = 110) or ventricular (n = 115) pacing. They were divided into subgroups with and without brady-tachy syndrome at time of randomisation. The occurrence of atrial fibrillation and t...

متن کامل

Incidence of atrial fibrillation and thromboembolism in a randomised trial of atrial versus dual chamber pacing in 177 patients with sick sinus syndrome.

OBJECTIVE To analyse the occurrence of atrial fibrillation (AF) and thromboembolism in a randomised comparison of rate adaptive single chamber atrial pacing (AAIR) and dual chamber pacing (DDDR) in patients with sick sinus syndrome and normal atrioventricular (AV) conduction, in which left atrial dilatation and decreased left ventricular fractional shortening had been observed in the DDDR group...

متن کامل

Retrospective analysis of reasons for failure of DDD pacemaker implantation in patients operated on between 1993 and 2005.

BACKGROUND During implantation of a DDD pacemaker the following difficulties may be encountered: venous anomalies (the absence of vessels of adequate calibre or difficulty in subclavian vein puncture), arrhythmias during implantation (episodes of atrial flutter/fibrillation while the atrial leads are being positioned), lack of mechanical stability of the electrode in the heart chamber and inabi...

متن کامل

Radiotherapy and pacemaker: 80 Gy to target close to the device may be feasible.

Influence of right ventricular stimulation site on left ventricular function in atrial synchronous ventricular pacing. J Am Coll Cardiol 1999;33:317–23. 22. de Cock CC, Giudici MC, Twisk JW. Comparison of the haemodynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing: a quantitative review. Europace 2003;5:275–8. 23. Schaldach M, Ebner E, Hutten H, von Kno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 8 7  شماره 

صفحات  -

تاریخ انتشار 2006