Comparison of serum folate species analyzed by LC-MS/MS with total folate measured by microbiologic assay and Bio-Rad radioassay.

نویسندگان

  • Zia Fazili
  • Christine M Pfeiffer
  • Mindy Zhang
چکیده

BACKGROUND The Bio-Rad QuantaPhase II radioassay (BR), used for 25 years to measure total folate (TFOL) concentrations for the National Health and Nutrition Examination Survey (NHANES), will be discontinued in 2007. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) or a microbiologic assay (MA) will be used in the future. METHODS We measured folate species by LC-MS/MS and TFOL by MA and BR in 327 serum samples. RESULTS LC-MS/MS measured 5-methyltetrahydrofolic acid (5CH(3)THF; 82%), folic acid (FA; 8%), 5-formyltetrahydrofolic acid (5CHOTHF; 6%), tetrahydrofolic acid (THF; 4%), and 5,10-methenyltetrahydrofolic acid (5,10CH=THF; 0%). The sum of the folate species correlated well with TFOL measured by MA (R(2) = 0.97) and BR (R(2) = 0.91). Compared with LC-MS/MS results, MA and BR values were significantly lower (-6% and -29%, respectively); however, these differences were concentration dependent. The MA almost completely recovered folates added to serum samples except for FA [69% (3%)] and THF [36% (10%)]. The BR underrecovered 5CH(3)THF [61% (9%)] and 5CHOTHF [38% (14%)] and overrecovered 5,10CH=THF [234% (32%)]. Multiple linear regression models with log-transformed data yielded a good fit for converting BR data to MA or LC-MS/MS data and MA data to LC-MS/MS data. CONCLUSIONS The good correspondence between the sum of folate species determined by LC-MS/MS and TFOL determined by MA makes these 2 assays interchangeable. The BR produces much lower results, on average, probably because of 5CH(3)THF underrecovery. The conversion equations provided could be used for future NHANES time trend analyses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of 5,10-methylenetetrahydrofolate reductase polymorphism on whole-blood folate concentrations measured by LC-MS/MS, microbiologic assay, and bio-rad radioassay.

BACKGROUND The 5,10-methylenetetrahydrofolate reductase (NADPH) (MTHFR) C677T polymorphism may affect whole-blood folate pattern measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and total folate measured by LC-MS/MS, microbiologic assay, and Bio-Rad radioassay (BR). METHODS We analyzed 171 whole blood hemolysates from 2 blood banks for folate pattern and total folate conc...

متن کامل

Determination of folate vitamers in human serum by stable-isotope-dilution tandem mass spectrometry and comparison with radioassay and microbiologic assay.

BACKGROUND Current clinical methods for folate give different results and cannot measure the various forms of folate. We developed an isotope-dilution tandem mass spectrometric method coupled to liquid chromatography (LC/MS/MS) as a candidate reference method for 5-methyltetrahydrofolic acid (5MeTHF), 5-formyltetrahydrofolic acid (5FoTHF), and folic acid (FA) in human serum. METHODS We quanti...

متن کامل

Measurement of folate in fresh and archival serum samples as p-aminobenzoylglutamate equivalents.

BACKGROUND The development of accurate and precise folate assays has been difficult, mainly because of folate instability. Large interassay and interlaboratory differences have been reported. We therefore developed a serum folate assay that measures folate and putative degradation products as p-aminobenzoylglutamate (pABG) equivalents following oxidation and acid hydrolysis. METHODS Serum was...

متن کامل

Biomarkers of folate status in NHANES: a roundtable summary123456

A roundtable to discuss the measurement of folate status biomarkers in NHANES took place in July 2010. NHANES has measured serum folate since 1974 and red blood cell (RBC) folate since 1978 with the use of several different measurement procedures. Data on serum 5-methyltetrahydrofolate (5MTHF) and folic acid (FA) concentrations in persons aged ≥60 y are available in NHANES 1999-2002. The roundt...

متن کامل

Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood.

We compared results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2007