An Adverse Implication of Radiation Therapy for Implant-Retained Maxillofacial Prostheses.

نویسندگان

  • Tadashi Akamatsu
  • Ushio Hanai
  • Megumi Kobayashi
  • Takahiko Kuroki
  • Yotaro Tsunoda
  • Muneo Miyasaka
چکیده

We report the 19-year postoperative course of a patient whose maxillary defect was reconstructed with maxillofacial implant-retained facial prostheses. The patient received 60 Gy of radiation therapy. Adjunctive hyperbaric oxygen therapy was administered and four 4.0-mm long maxillofacial implants were inserted. Four years and 6 months after insertion surgery, two of the four implants were lost and the others showed bone regression in the surrounding bone. All implants were replaced with Epitec System maxillofacial implants placed in non-irradiated bone. Eleven years and 6 months after replacement, the Epitec System has been maintaining good and firm osseointegration. Appropriate selection of implant sites and no history of radiation therapy are keys to successful implant reconstruction. However, adjunctive hyperbaric oxygen therapy is believed to be effective, osseointegrated implant should be inserted at a point appropriately distant from an irradiated lesion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rehabilitation of a missing ear with an implant retained auricular prosthesis.

Burns can leave a patient with a severely debilitating disability even after treatment. The objectives of burn rehabilitation are to minimize the adverse effects caused by the injury while rehabilitating the patient's physical and psychological well-being, maximizing social integration. Long-term success of maxillofacial prostheses mainly depends on the retention. Extra oral implant retained pr...

متن کامل

Telescopic prostheses for implants.

This retrospective study investigated the outcome of 73 telescopic implant-supported fixed prostheses. Fifty-four prostheses were entirely cement-retained, and 19 incorporated a screw-clamping unit. The rate of complications was low and in most cases minor in nature. Cement-retained prostheses involving a distal cantilevered extension required the greatest postoperative maintenance. Despite the...

متن کامل

Current state of craniofacial prosthetic rehabilitation.

PURPOSE This study aimed to review the current state of the techniques and materials used to rehabilitate maxillofacial defects. MATERIALS AND METHODS The MEDLINE and EMBASE databases were searched for articles pertinent to maxillofacial prostheses published from January 1990 to July 2011. The main clinical stages were the subject of analysis. RESULTS A multidisciplinary approach is preferr...

متن کامل

Cement- and screw-retained implant-supported prostheses: up to 10 years of follow-up of a new design.

PURPOSE This retrospective study investigated treatment outcomes over 10 years of a new prosthesis design in implant prosthodontics that uses a combined cement- and screw-retained principle. MATERIALS AND METHODS The clinical data of 78 implant-supported prostheses were examined. Each prosthesis incorporated at least 1 screw-retained element and 1 or more cement-retained telescopic units. One...

متن کامل

Cement-retained versus screw-retained implant restorations: a critical review.

This article presents a comparison of screw-retained and cement-retained implant prostheses based on the literature. The advantages, disadvantages, and limitations of the 2 different types of restorations are discussed, because it is important to understand the influence of the attachment mechanism on many clinical aspects of implant dentistry. Several factors essential to the long-term success...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Tokai journal of experimental and clinical medicine

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2015