Natural linewidth chemical shift imaging (NL-CSI).

نویسندگان

  • Adil Bashir
  • Dmitriy A Yablonskiy
چکیده

The discrete Fourier transform (FT) is a conventional method for spatial reconstruction of chemical shifting imaging (CSI) data. Due to point spread function (PSF) effects, FT reconstruction leads to intervoxel signal leakage (Gibbs ringing). Spectral localization by imaging (SLIM) reconstruction was previously proposed to overcome this intervoxel signal contamination. However, the existence of magnetic field inhomogeneities creates an additional source of intervoxel signal leakage. It is demonstrated herein that even small field inhomogeneities substantially amplify intervoxel signal leakage in both FT and SLIM reconstruction approaches. A new CSI data acquisition strategy and reconstruction algorithm (natural linewidth (NL) CSI) is presented that eliminates effects of magnetic field inhomogeneity-induced intervoxel signal leakage and intravoxel phase dispersion on acquired data. The approach is based on acquired CSI data, high-resolution images, and magnetic field maps. The data are reconstructed based on the imaged object structure (as in the SLIM approach) and a reconstruction matrix that takes into account the inhomogeneous field distribution inside anatomically homogeneous compartments. Phantom and in vivo results show that the new method allows field inhomogeneity effects from the acquired MR signal to be removed so that the signal decay is determined only by the "natural" R2 relaxation rate constant (hence the term "natural linewidth" CSI).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemical shift imaging in the head and neck at 3T: initial results.

PURPOSE To determine the optimal method to correct air and tissue susceptibility differences in the head and neck to allow proton ((1)H) chemical shift imaging (CSI) to be performed at 3T. MATERIALS AND METHODS Shimming protocols (iterative, first-order, and second-order) and perfluorocarbon (PFC) pads were evaluated using water peak linewidth measurements obtained from single-voxel magnetic ...

متن کامل

Region and volume dependencies in spectral linewidth assessed by H 2D chemical shift imaging in the monkey brain at 7T

High magnetic fields increase the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS). In contrast, spectral peaks are broadened in vivo at higher field strength due to stronger susceptibility-induced effects. Strategies to minimize the spectral linewidth are therefore of critical importance. In the present study, H 2D chemical shift imaging (CSI) at short echo times wa...

متن کامل

Theoretical evaluation and comparison of fast chemical shift imaging methods.

Magnetic resonance chemical shift imaging (CSI) is becoming the method of choice for localized NMR spectroscopic examinations, allowing simultaneous detection of NMR spectra from a large number of voxels. The main limitation of these methods is their long experimental duration. A number of fast CSI experiments have been presented, promising to reduce that duration. In this contribution the crit...

متن کامل

Dixon and Chimera: Two methods for fast separation of PFC compounds with small chemical shift difference

Introduction Perfluorocarbon (PFC) emulsions have been widely used for cell tracking studies [1,2] and many other biological applications [3]. In contrast to conventional H contrast agents, F markers provide unambiguous signal in vivo due to the low natural abundance of fluorine in living organisms. Furthermore, fluorine markers can possess a unique spectral signal, a further advantage of F MR....

متن کامل

Fast 31P chemical shift imaging using SSFP methods.

Steady-state free precession (SSFP) methods have been very successful due to their high signal and short imaging times. These properties make them good candidates for applications that intrinsically suffer from low signal such as low gamma nuclei imaging. A new chemical shift imaging (CSI) technique based on the SSFP signal formation has been implemented and applied to (31)P. The signal propert...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 56 1  شماره 

صفحات  -

تاریخ انتشار 2006